D-F0382 NP-266/366 Product specifications Ver.1.10
20
4.6 Self print
1) By performing self-diagnostic print following items are checked.
a) Proper function of control circuitry
b) Proper function of printer mechanism
c) Print
quality
d) Control F/W version
e) DIP switch setting status
f) Correct function of paper out sensor
2) Start and end of self diagnostic print
Open the front cover. Close the cover while pressing the FEED switch and release the FEED
switch within 5 seconds. Self diafnostic print will take place.
The self diagnostic print automatically ends when a preset number of characters are finished
printing. While printing, the printer is in Off-line mode. Without paper is loaded, no print occurs.
4.7 Buffer full print
If there remains data in the buffer after one line of data is received, printer automatically prints
preceding data. The volume of buffer full data varies depending on ASCII characters (Font A, B)
or bit images.(Line mode)
4.8 Presenter drive
Presenter NPT-305 can be drived.
※
A type only
※
Print speed is max. 150 mm/sec for A type.