background image

GW1200 Gateway Installation & Configuration Guide 

 

34 

The warranty set forth above shall not be enlarged and no obligation or liability shall arise 

out of STANLEY’s rendering of technical advice, facilities or service in connection with Customer's 
purchase of the STANLEY Healthcare AeroScout® Products.   
 

Except for the foregoing warranties, which shall be the exclusive warranties with respect to 
any Products, STANLEY MAKES NO WARRANTY OR REPRESENTATION OF ANY KIND, 
EXPRESS OR IMPLIED, WRITTEN OR ORAL,  REGARDING INFORMATION GIVEN OR THE 
PRODUCTS OR SERVICES SUPPLIED AND EXPRESSLY DISCLAIMS ALL EXPRESS AND 
IMPLIED WARRANTIES, REPRESENTATIONS AND CONDITIONS, INCLUDING WITHOUT 
LIMITATION ALL WARRANTIES AND CONDITIONS OF QUALITY, NON-INFRINGEMENT, 
MERCHANTABILITY AND SUITABILITY OR FITNESS FOR A PARTICULAR

 

PURPOSE TO 

THE EXTENT PERMITTED BY LAW. STANLEY WILL NOT BE LIABLE FOR CONSEQUENTIAL, 
INCIDENTAL, INDIRECT OR PUNITIVE DAMAGES FOR ANY CAUSE OF ACTION, WHETHER 
IN CONTRACT, TORT OR OTHERWISE.  Consequential, incidental and indirect damages 
include, but are not limited to, lost profits, lost revenue and loss of business opportunity, 
whether or not STANLEY was aware or should have been aware of the possibility of these 
damages.  

 

 

 

Содержание GW1200

Страница 1: ...GW1200 GATEWAY INSTALLATION CONFIGURATION GUIDE ...

Страница 2: ... other trademarks or registered trademarks referenced herein Hugs Infant Protection System is a registered trademark of Stanley Black Decker or its affiliates Cisco is a trademark of Cisco Systems Inc Sun Sun Microsystems the Sun Logo Java JRE and all other Sun trademarks logos product names service names program names and slogans that are referred to or displayed in this document are trademarks o...

Страница 3: ...and Power Connections to the GW1200 Gateway 8 Resetting the GW1200 Gateway IP Address 11 GW1200 Naming Convention 12 Adding Configuring the GW1200 via AeroScout Engine Manager AEM 13 Updating Firmware Gateways 14 Mounting the Gateway 15 Fixing the Controller to a Floating Ceiling 15 GW1200 and Accessories Model Numbers 29 GW1200 Specifications 30 Regulatory Compliance Warranty 31 FCC 31 Industry C...

Страница 4: ...ay is used to help provide the core layers of protection Exit Tamper Tag Loose and Supervision in either a Gateway only deployment with a dedicated network of Gateways providing Wi Fi receiver coverage or with strategically placed Gateways augmenting the facility s existing network of Access Points in the desired protected areas The Gateway may also be incorporated with additional use cases as det...

Страница 5: ...ation Engine Continuous Gateway Supervision The GW1200 Gateway device status is monitored at all times by the AeroScout Location Engine MobileView generates an alert if communication with the Gateway is compromised Additionally to provide full device supervision capabilities the receiver modules in the Gateway will switch into a test transmission mode simulating Tag message transmission to verify ...

Страница 6: ...ors The GW1200 Gateway has a single LED that changes color based on the device status as follows Constant Green The Gateway is on and working correctly Constant Orange Gateway failure or network down No LED indication Gateway is off Figure 2 GW1200 Gateway LED Indicator ...

Страница 7: ...tiation mode for the Gateway to operate at 100 Mb 2 Power Jack Accepts an input voltage of 24 48V DC This is a standard 5 mm outer 2 5 mm internal jack connector for direct power supply A power adapter is not supplied with the Controller and can be purchased separately When PoE is used this connector becomes redundant 3 IN RS 232 and OUT RS 232 Connector RJ 45 connector RS 232 is used as a console...

Страница 8: ... the Gateway s power jack Note The GW1200 requires approximately 8 W of power When connecting a Gateway to a direct power source with one of the above options verify that the provided power level is sufficient The device must only be powered by a limited marked LPS or NEC class 2 power supply PoE Switch If the network has a Power over Ethernet infrastructure a CAT 5 6 Ethernet cable connects the P...

Страница 9: ... s IN connector is connected to the network The injector s OUT connector is connected to the Gateway s LAN connector 110 220 VAC to 48 VDC Power Supply Adapters These adapters convert 110 VAC or 220 VAC to 48 VDC Figure 4 110 220 VAC to 48 VDC Adapter The adapter is connected to the GW1200 Gateway power jack The network must be connected separately to the Gateway LAN connector ...

Страница 10: ...Current Available Power Maximum of Exciters with One Source PoE single port injector 100 240 VAC 50 60 Hz 48 VDC 0 32 A 1 15 4 W One GW1200 Gateway Standard PoE 802 3af switch port 2 48 VDC 0 32 A 1 15 4 W One GW1200 Gateway External power adapter 48 VDC 0 4 A 20 W One GW1200 Gateway Note To prevent excessive power loss PoE cables must not exceed 100 m 330 in length ...

Страница 11: ... Address The GW1200 Gateway IP address can be reset to the factory default value of 192 168 1 178 The Gateway does not support DHCP requiring all device addresses to be manually configured Press the IP Reset button with a ballpoint pen for at least 10 seconds Figure 5 IP Reset Button ...

Страница 12: ... In line with our recommended best practice when configuring the GW1200 Gateways in the AeroScout Location Engine use recognizable names for the GW1200 Gateways as the Gateway names are used in the alert distribution and should provide clear information for the alert location ...

Страница 13: ...d to appear on the map as an Exciter Multiple Gateways can be added to the Location Engine using the Load Devices option on the Repository tab or the Scanning for Devices option after setting their IP addresses and connecting them to the network For more information refer to the AeroScout Location Engine Deployment Guide Receivers section under Adding Receivers ...

Страница 14: ...nfiguration Guide 14 Updating Firmware Gateways Updating the Firmware of GW1200 Gateways is performed in the Engine Manager For more information refer to the AeroScout Location Engine Deployment Guide Upload Exciter Firmware section ...

Страница 15: ...ommendations Fixing the Controller to a Floating Ceiling Mounting on a Wide grid with Flush Tiles For this mounting option no mounting kit is required Attach the device to the false ceiling using the ceiling mounts located on the bottom casing of the device 1 Align the Mounting clips with the wide grid 2 Twist and click the Exciter into place ...

Страница 16: ...tion Mounting Off Grid For this mounting option the following parts from the Heavy Duty Off Grid Exciter Mounting kit EXAC HDUTY 1000 are required Part Letter Part Name Quantity Image A Mounting Adaptor 1 E x 3 Phillips Screw 2 G Hex Nut 6 I Spring washer 2 H Flat washer 2 D Bracket 512HD 1 ...

Страница 17: ...ith 1 2 Step 2 Fasten 2 Screws E on the 512HD Bracket D with 1 Flat Washer H and 1 Spring Washer I Set the distance between the Screws using the Adaptor A 3 Drill 2 holes in the designated for installation ceiling tile for the Screws E Use the assembled 512HD Bracket D to mark the location of the holes Holes should be 5 16 or 8mm in diameter ...

Страница 18: ... Assembled 512HD Bracket D on the tile Fix in place 2 Nuts G on each of the Screws E leaving enough screw length 2 5 or 10mm to mount the Adaptor 5 Mount the Adaptor using 2 Nuts G using a 7 16 nut driver 6 Mount the Exciter onto the Adaptor A on the ceiling tile ...

Страница 19: ...GW1200 Gateway Installation Configuration Guide 19 Figure 7 Correct Complete Mounting Position ...

Страница 20: ...e required Part Letter Part Name Quantity Image A Mounting Adaptor 1 C Narrow Grid Clip 9 16 Clip with 8 Stud 2 J 8 32 Hex Nyloc Nut 2 1 Cut the Mounting Adaptor A so that only Section 1 remains Use Mount Adaptor part marked with 1 2 Assemble the Grid Clips C on the Adaptor A Lock each Clip C with Hex Nut J The Nuts should be loose at this stage to allow easy insertion onto the grid ...

Страница 21: ...with Mount Adaptor A onto the ceiling grid Push the clips against the grid and twist them until they lock turn clockwise 4 Fasten the Adaptor A to the Clips C by tightening Nuts J into their final position using a 11 32 Nut Driver 5 Mount the Exciter onto the Mounting Adaptor A ...

Страница 22: ...GW1200 Gateway Installation Configuration Guide 22 Figure 8 Correct Complete Mounting Position ...

Страница 23: ...STD 1000 are required Part Letter Part Name Quantity Image A Mounting Adaptor 1 B Wide Grid Clip 15 16 Clip with 1 4 Stud 2 G 1 4 Hex Nut 2 1 Cut the Mounting Adaptor A so that only Section 1 remains Use Mount Adaptor part marked with 1 2 Assemble the Grid Clips B on the Adaptor A Lock each clip B with Hex Nut G Nuts should be loose at this step to allow easy insertion onto the grid ...

Страница 24: ...nt Adaptor A onto the ceiling grid Push the clips against the grid and twist them until they lock Fasten the Clip s stud B against the grid using a flat screwdriver turn clockwise 4 Tighten Nuts G to final position using a 7 16 Nut Driver 5 Mount the Exciter onto the Mounting Adaptor A ...

Страница 25: ... a Slotted Grid For this mounting option the following parts from the Standard Exciter Mounting kit EXAC STD 1000 are required Part Letter Part Name Quantity Image A Mounting Adaptor 1 F For Slotted Grid 1 4 x0 625 Phillips screw 2 G 1 4 Hex Nut 2 1 Cut the Mounting Adaptor A so that only Section 1 remains ...

Страница 26: ...r part marked with 1 2 Assemble the Screws F on the Adaptor Lock each Screw F with Hex Nut G Nuts should be loose at this step to allow easy insertion into the slotted grid 3 Mount the Adaptor A onto the Slotted Grid by sliding the screw heads Screw F through the slots ...

Страница 27: ...ition Mounting the Gateway on a Wall While not normal practice there may be occasions particularly in older facilities where the ceilings are already congested when wall mounting of the GW1200 Gateway may be the only viable option The Gateway is shipped with a mounting template which can be used to measure the holes for mounting the Gateway on a wall See Figure 11 The mounting plate supplied with ...

Страница 28: ...re the template is level 2 Mark the four holes for the screws through the template 3 Remove the template 4 Drill the holes for the screws 5 Anchor the screws into the wall leaving 10mm of each of the screws exposed Use appropriate screws and or anchoring plugs 6 Mount the Gateway with the STANLEY Healthcare logo facing up onto the 4 screws The Gateway s back panel has 4 mounting brackets for this ...

Страница 29: ...ounting in the center of a floating ceiling tile when mounting on the ceiling grid is not possible or when heavy duty mounting is required Fits the following Device Models EX3210 EX4100 EX4110 EX4200 EX5000 EX5200 EX5500 External Speaker Antenna and GW1200 Each kit can be used for a single device Standard Exciter Mounting Kit EXAC STD 1000 Standard Exciter Mounting Kit for Exciters and Gateways an...

Страница 30: ...ical Dimensions 245 mm X 200 mm X 60 mm 9 6 in x 7 9 in x 2 4 in Weight 865 g 31oz Housing Polycarbonate and ABS Network Interface Ethernet RJ 45 Wi Fi 802 11 b g n Power Input voltage 24 48 VDC PoE 802 3af 48 VDC Maximum power consumption 10 W Environmental Operating temperature 0 to 50 C 32 F to 122 F Humidity 0 to 95 non condensing ...

Страница 31: ...are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equip...

Страница 32: ...R d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptibled en compromettrelefonctionnement RoHS RoHS Directive 2011 65 EU CE Conformance IEC 60601 1 2005 EN ...

Страница 33: ...50 sterilization cycles from the date of delivery provided however that sterilization outside of environmental specifications approved in any applicable user documentation voids all warranties Extended Warranty STANLEY offers an extended warranty for a fee on AeroScout products Within the one 1 year of the standard warranty additional warranty of two 2 years may be purchased Additional warranty ye...

Страница 34: ...NFORMATION GIVEN OR THE PRODUCTS OR SERVICES SUPPLIED AND EXPRESSLY DISCLAIMS ALL EXPRESS AND IMPLIED WARRANTIES REPRESENTATIONS AND CONDITIONS INCLUDING WITHOUT LIMITATION ALL WARRANTIES AND CONDITIONS OF QUALITY NON INFRINGEMENT MERCHANTABILITY AND SUITABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW STANLEY WILL NOT BE LIABLE FOR CONSEQUENTIAL INCIDENTAL INDIRECT OR PU...

Страница 35: ... Healthcare s By Your Side Lifetime Customer Care commitment to ensure that every customer achieves success and realizes the full value of their investment through consulting training implementation and integration services STANLEY Healthcare is proud to be part of Stanley Black Decker Inc For more information visit stanleyhealthcare com Follow STANLEY Healthcare on Facebook Twitter LinkedIn and Y...

Отзывы: