CONDENSING UNIT SPECIFICATIONS (cont.) 

 

 

Master-Bilt®  
Model 

 

Cond Unit/Comp 
Model 

 

Compressor 
Model 

 

BTU/HR Capacity At 

Room Temp. With a 

10° TD, 90° Ambient

 

Ref.

 

Base 

Size 

(See 

pp. 39-

41)

 

H.P.

 

Connections

 

MCA

 

Voltage

 

-20

 

-10

 

0

 

Liquid

 

Suction

 

MCLZ0021B  

KANB-005E-CAV  

KANB-005E-CAV  

1249   1911   2719   R-404A   M1  

.5  

3/8  

5/8  

13  

208-230/60/1  

MCLZ0031B  

KAMB-007E-CAV  

KAMB-007E-CAV  

2512   3433   4554   R-404A   M1  

.75  

3/8  

7/8  

13  

208-230/60/1  

MCLZ0031C  

KAMA-007E-TAC  

KAMA-007E-TAC  

2285   3186   4262   R-404A   M1  

.75  

3/8  

7/8  

13  

208-230/60/3  

MCLZ0051B  

KAJB-010E-CAV  

KAJB-010E-CAV  

3139   4243   5562   R-404A   M1  

1  

3/8  

7/8  

13  

208-230/60/1  

MCLZ0051C  

KAJA-011E-TAC  

KAJA-011E-TAC  

3050   4186   5533   R-404A   M1  

1  

3/8  

7/8  

13  

208-230/60/3  

MCLZ0071B  

KALB-015E-CAV  

KALB-015E-CAV  

4993   6462   8207   R-404A   M1  

1.5  

3/8  

7/8  

16  

208-230/60/1  

MCLZ0071C  

KALA-016E-TAC  

KALA-016E-TAC  

4933   6408   7973   R-404A   M1  

1.5  

3/8  

7/8  

13  

208-230/60/3  

MCLZ0081B  

KATB-015E-CAV  

KATB-015E-CAV  

5841   7528   9143   R-404A   M1  

1.5  

3/8  

7/8  

16  

208-230/60/1  

MCLZ0081C  

KATA-015E-TAC  

KATA-015E-TAC  

5851   7438  

0  

R-404A   M1  

1.5  

3/8  

7/8  

13  

208-230/60/3  

MCLZ0101B  

EAVB-021E-CAV  

EAVB-021E-CAV  

6999   9104   11804   R-404A   M2  

2  

1/2  

7/8  

24  

208-230/60/1  

MCLZ0101BQ  

EAVB-021E-CAV  

EAVB-021E-CAV  

6999   9104   11804   R-404A   M2  

2  

1/2  

7/8  

24  

208-230/60/1  

MCLZ0101C  

EAVA-021E-TAC  

EAVA-021E-TAC  

6169   8755   11678   R-404A   M2  

2  

1/2  

7/8  

19  

208-230/60/3  

MCLZ0101K  

EAVB-021E-CAV  

EAVB-021E-CAV  

6999   9104   11804   R-404A   M2  

2  

1/2  

7/8  

24  

200-220/50/1  

MCLZ0111B  

3ABB-032E-CAB  

3ABB-032E-CAB  

7694   10372   13413   R-404A   M2  

3  

1/2  

7/8  

24  

230/60/1  

MCLZ0111C  

3ABA-031E-TAC  

3ABA-031E-TAC  

7364   10343   13556   R-404A   M2  

3  

1/2  

7/8  

19  

208-230/60/3  

MCLZ0111KQ  

3ABB-032E-CAB  

3ABB-032E-CAB  

7694   10372   13413   R-404A   M2  

3  

1/2  

7/8  

24  

200-220/50/1  

MCLZ0141B  

LAHB-032E-CAB  

LAHB-032E-CAB  

9948   13799   18139   R-404A   M3  

3  

1/2  

1 1/8  

28  

230/60/1  

MCLZ0141C  

LAHA-032E-TAC  

LAHA-032E-TAC  

10083   13903   18238   R-404A   M3  

3  

1/2  

1 1/8  

26  

208-230/60/3  

MCLZ014KC  

LAHA-032E-TAC  

LAHA-032E-TAC  

10324   14294   18827   R-404A  

T  

3  

1/2  

1 1/8  

26  

208-230/60/3  

MCLZ0171B  

NRD1-040E-CFB  

NRD1-040E-CFB  

12434   16915   21760   R-404A   M3  

4  

1/2  

1 1/8  

44  

230/60/1  

MCLZ0171C  

NRD1-032E-TFC  

NRD1-032E-TFC  

12822   17291   22136   R-404A   M3  

3  

1/2  

1 1/8  

32  

208-230/60/3  

MCLZ076RC  

9TL2-076E-TFC-251  

 

18600   24700   31600   R-404A   MAC   7.5  

7/8  

1 3/8  

45  

208-230/60/3  

MCLZ080RC  

S4N-8.2Y (Bitzer)  

S4N-8.2Y (Bitzer)   21907   27942   34977   R-404A   MAC   8.0  

7/8  

1 3/8  

50  

208-230/60/3  

MCLZ100RC  

9TH2-101E-TFC-252 

 

24800   32500   41200   R-404A   MAC   10.0   7/8  

1 3/8  

60  

208-230/60/3  

MCLZ120RC  

S4G-12.2Y  

S4G-12.2Y  

35621   44811   55168   R-404A   MAC   12.0   7/8  

1 5/8  

65  

208-230/60/3  

*Deduct 7% for each 10 degree rise over 90°F. 
**MCA does not include evaporator amps for room temperature 35°F and above. 

 

 

Master-Bilt®  
Model 

 

Cond 
Unit/Comp 
Model 

 

Compressor 
Model 

 

BTU/HR Capacity At Room 

Temp. With a 10° TD, 90° 

Ambient

 

Ref.

 

Base 

Size 

(See 

pp.  

39-41)

 

H.P.

 

Connections

 

MCA

 

Voltage

 

20

 

30

 

35

 

40

 

Liquid 

 

Suction

 

MCMZ0381C  

NRB2-040E-TFC   NRB2-040E-TFC   37899 

 

 

 

R-404A 

M3 

1/2 

1 1/8 

44  208-230/60/3 

MDHY0371C  

2DF3-030E-TFC  

2DF3-030E-TFC   20931  26800  31900  37000  R-134A 

M5 

5/8 

1 3/8 

44  200-220/60/3 

MDHZ0511C  

2DC3-050E-TFC   2DC3-050E-TFC   31997  40969  45362  49969  R-404A 

M5 

5/8 

1 3/8 

44  200-230/60/3 

*Deduct 7% for each 10 degree rise over 90°F. 
**MCA does not include evaporator amps for room temperature 35°F and above. 

 
 

Master-Bilt®  
Model 

 

Cond Unit/Comp 
Model 

 

Compressor 
Model 

 

BTU/HR Capacity At 

Room Temp. With a 

10° TD, 90° Ambient

 

Ref.

 

Base 

Size 

(See 

pp. 39-

41)

 

H.P.

 

Connections

 

MCA

 

Voltage

 

-20

 

-10

 

0

 

Liquid

 

Suction

 

MDLZ0201B  

2DF3F16KE-CFB  

2DF3F16KE-CFB   14134  18469  23298  R-404A 

M5 

1/2 

1 1/8 

40 

230/60/1 

MDLZ0201C  

2DF3-030E-TFC  

2DF3-030E-TFC  

14838  19518  24878  R-404A 

M5 

1/2 

1 1/8 

38 

208-230/60/3 

MDLZ0231C  

2DL3-040E-TFC  

2DL3-040E-TFC  

17605  22958  29022  R-404A 

M5 

1/2 

1 1/8 

42 

208-230/60/3 

MDLZ0291C  

2DB3-060E-TFC  

2DB3-060E-TFC  

22203  29187  36996  R-404A 

M5 

5/8 

1 3/8 

47 

208-230/60/3 

MDLZ0331C  

3DA3A060E-TFC  

3DA3A060E-TFC   25189  32417  40682  R-404A 

M5 

5/8 

1 3/8 

50 

208-230/60/3 

*

Deduct 7% for each 10 degree rise over 90°F. 

**MCA does not include evaporator amps for room temperature 35°F and above.

 

Содержание BCHX0050B

Страница 1: ...tion System Installation Operations Manual 908 Highway 15 North New Albany MS 38652 Phone 800 684 8988 Fax 800 232 3966 www master bilt com 2015 Master Bilt Products an unincorporated division of Stan...

Страница 2: ...Walk In 9 Evaporator and Drain line installation Instructions 9 10 Electrical 11 Refrigerant Piping 11 Leak Check 12 Evacuation Dehydration and Start Up 12 Evacuation Procedure 12 Finish Charging Pro...

Страница 3: ...refrigeration and electrical work DANGER Equipment MUST be properly grounded Improper or faulty hook up of electrical components of the refrigeration units can result in severe injury or death All el...

Страница 4: ...following signal words are used in the warnings and safety messages DANGER Severe injury or death WILL occur if you ignore the message WARNING Severe injury or death CAN occur if you ignore the messa...

Страница 5: ...solenoid valve shipped loose Timer Generously sized condenser for 105 to 110 ambient Large liquid receiver good for maximum 250 ft line run Defrost heater contactor when required Compressor contactor...

Страница 6: ...r maximum 100 ft line run One year limited compressor warranty Components may vary depending on horsepower and application Consult our factory for verification of standard and optional components Pres...

Страница 7: ...P 025 2 H P 050 5 H P 100 10 H P 220 22 H P 350 35 H P 015 1 H P 028 3 H P 060 6 H P 120 12 H P 250 25 H P 400 40 H P BTU HR RATING EXPLANATION NOTE APPLIES TO M SERIES ONLY Room temp H Nominal BTUH...

Страница 8: ...n immediate inspection of your concealed damage item Crating material MUST be retained to show the inspector from the truck line INSTALLATION INSTRUCTIONS I Handling and Placement of Condensing Unit T...

Страница 9: ...lifting and mounting to the ceiling to prevent sheet metal damage EVAPORATOR INSTALLATION INSTRUCTIONS A Do not install the evaporator too close to door openings to prevent icing problems B Minimum c...

Страница 10: ...ceptable b Drain lines must exit the freezer or cooler as quickly as possible and must have a pitch of at least 1 8 inch foot downward or meet the local code requirements c Drain lines must have indiv...

Страница 11: ...ube cutter DO NOT CUT TUBING WITH A SAW Note The liquid line size is determined by conventional piping practices for air and electric defrost use chart on pages 15 16 For reverse cycle defrost the liq...

Страница 12: ...YSTEM COMPRESSOR AS A VACUUM PUMP DO NOT OPERATE COMPRESSOR WHILE SYSTEM IS IN A VACUUM EVACUATION PROCEDURE A Open all condensing unit service valves and relieve system pressure Also open any line va...

Страница 13: ...to high amperage The oil sight glass should be between 1 2 and 3 4 full during normal operation B Remote M Series Condensing Units 1 For models without head pressure control valve With the system oper...

Страница 14: ...accordance with the manufacturer s recommendations from inside wall or obstructions to rear of evaporator Drill holes through the walk in wall large enough to pass refrigeration lines electrical line...

Страница 15: ...and allow to run at least 24 hours before placing product into the walk in During the testing period you should Check the temperature holding range against the control setting On low temperature units...

Страница 16: ...ements of unit to power supply voltage E Set temperature control for desired temperature range F Check setting of thermostatic expansion valve for proper operation G Check sight glass for proper refri...

Страница 17: ...5 16 Rev B 57 02497 NOTE Sizes specified are for Type L copper tubing...

Страница 18: ...5 16 Rev B 57 02497 18 NOTE Sizes specified are for Type L copper tubing...

Страница 19: ...8 to 1 3 8 OD lines and 10 feet for 1 5 8 and 2 1 8 OD lines 3 Where condensation dripping would be objectionable insulate suction lines and where the sun could adversely affect performance insulate b...

Страница 20: ...ge Charge Charge Charge Charge Unit to Fill to Fill Unit to Fill to Fill Unit to Fill to Fill Model R 22 R 404A Model R 22 R 404A Model R 22 R 404A BCH 0300 8 4 7 1 BHMX0300 8 4 MCHX0060 4 2 BCH 0500...

Страница 21: ...5 16 Rev B 57 02497 21...

Страница 22: ...TFD 2DC3 050E TFD 41437 46041 R 22 C 5 5 8 1 3 8 16 460 60 3 BCHX050LC 2DC3 050E TFC 2DC3 050E TFC 42017 46685 R 22 D 5 5 8 1 3 8 34 208 230 60 3 BCHX050XC 2DD3 050E TFC 2DD3 050E TFC 51948 57720 R 22...

Страница 23: ...075E TFC 63039 70043 R134a E 7 5 1 1 8 1 3 8 46 208 230 60 3 BCHY1000C 3DS3 100E TFC 3DS3 100E TFC 102088 113431 R134a F 10 7 8 1 3 8 64 208 230 60 3 BCHY100XCC 3DS3 100E TFC 3DS3 100E TFC 102088 113...

Страница 24: ...EAVB 021E CAV 6489 8448 10773 R 404A B 2 3 8 7 8 26 208 230 60 1 BCLZ0200C EAVA 021E TAC EAVA 021E TAC 6489 8448 10773 R 404A B 2 3 8 7 8 20 208 230 60 3 BCLZ0200E EAVA 021E TAD EAVA 021E TAD 6489 844...

Страница 25: ...BCLZ1000C 3DS3 100E TFC 3DS3 100E TFC 39632 50630 62719 R 404A E 10 7 8 1 3 8 71 208 230 60 3 BCLZ1000E 3DS3 100E TFD 3DS3 100E TFD 39632 50630 62719 R 404A E 10 7 8 1 3 8 37 460 60 3 BCLZ1000G 3DS3 1...

Страница 26: ...3DF3 1200 TFC 106882 R 22 F 12 7 8 1 5 8 88 208 230 60 3 BCMX120XE 3DK3 1200 TFD 3DK3 1200 TFD 119511 R 22 F 12 7 8 1 5 8 61 460 60 3 BCMX120YE 4P 15 2 4P 15 2 119511 R 22 F 12 7 8 1 5 8 61 460 60 3 B...

Страница 27: ...00E 2DC3 050E TFD 2DC3 050E TFD 38257 R 404A C 5HP 5 8 1 3 8 21 460 60 3 BCMZ0750C 2DA3 075E TFC 2DA3 075E TFC 63130 R 404A D 7 5HP 5 8 1 3 8 64 208 230 60 3 BCMZ0750E 2DA3 075E TFD 2DA3 075E TFD 6313...

Страница 28: ...6 29962 R 22 C 3 1 2 7 8 20 200 230 60 3 BHHX0300E CR41KQ TFD CR41KQ TFD 26966 29962 R 22 C 3 1 2 7 8 10 460 60 3 BHHX030LC CR41KQ TF5 CR41KQ TF5 28004 31115 R 22 C 3 1 2 7 8 20 200 230 60 3 BHHX030RC...

Страница 29: ...4 5 8 7 8 24 200 230 60 3 BHHZ0500B CS33K3E PFV CS33K3E PFV 37373 41525 R 404A C 5 5 8 7 8 42 208 230 60 1 BHHZ0500C CS33K3E TF5 CS33K3E TF5 37373 41525 R 404A C 5 5 8 7 8 30 200 230 60 3 BHHZ050LC C...

Страница 30: ...200 230 60 3 BHMX025LB CRG3 0250 PFV CRG3 0250 PFV 18766 R 22 C 2 5 1 2 7 8 31 208 230 60 1 BHMX025NB CRG3 0250 PFV CRG3 0250 PFV 17907 R 22 C 2 5 1 2 7 8 28 208 230 60 1 BHMX025NC CRG3 0250 TF5 CRG3...

Страница 31: ...TFD 43650 48500 R 22 C 5 5 8 7 8 15 460 60 3 BSHX060LCC ZB45KCE TF5 ZB45KCE TF5 52200 58000 R 22 E 6 7 8 1 1 8 31 200 230 60 3 BSHX060VCC ZB45KCE TF5 ZB45KCE TF5 52200 58000 R 22 D 6 5 8 7 8 32 200 2...

Страница 32: ...11758 15047 18615 R 404A C 4 1 2 7 8 32 200 230 60 3 BSLZ040VCC ZF13K4E TF5 1 x TEL 5 24 11758 15047 18615 R 404A C 4 1 2 7 8 20 200 230 60 3 BSLZ040VCJ ZF13K4E TF5 ZF13K4E TF5 11758 15047 18615 R 404...

Страница 33: ...7 8 45 200 230 60 3 BSMX050VCM ZB38KCE TF5 ZB38KCE TF5 39100 43800 48500 R 22 C 5 5 8 7 8 45 200 230 60 3 BSMX050VCN ZB38KCE TF5 ZB38KCE TF5 39100 43800 48500 R 22 C 5 5 8 7 8 45 200 230 60 3 BSMX050V...

Страница 34: ...TFC 34517 38943 43539 R 22 M5 4 5 8 1 1 8 44 208 230 60 3 MCHX0501C NRA2 0500 TFC NRA2 0500 TFC 40155 44944 49973 R 22 M5 5 5 8 1 1 8 44 208 230 60 3 MCHZ0061B HAJB 005E CAV HAJB 005E CAV 5026 5505 5...

Страница 35: ...LAHA 032E TAC 10324 14294 18827 R 404A T 3 1 2 1 1 8 26 208 230 60 3 MCLZ0171B NRD1 040E CFB NRD1 040E CFB 12434 16915 21760 R 404A M3 4 1 2 1 1 8 44 230 60 1 MCLZ0171C NRD1 032E TFC NRD1 032E TFC 128...

Страница 36: ...12559 16081 18189 20387 R 22 M2 2 2 1 2 7 8 29 208 230 60 1 MHHX0221C CR28KQ TF5 CR28KQ TF5 12034 15408 17500 19711 R 22 M2 2 2 1 2 7 8 29 200 230 60 3 MHHX0251B CR33KQ PFV CR33KQ PFV 14383 18416 207...

Страница 37: ...CS10K6E TF5 CS10K6E TF5 10083 12911 14326 15671 R 404A M2 1 5 1 2 7 8 20 200 230 60 3 MHHZ0171CM CS10K6E TF5 CS10K6E TF5 10083 12911 14326 15671 R 404A M2 1 5 1 2 7 8 20 200 230 60 3 MHHZ0191B CS12K6...

Страница 38: ...K6E PFV CF06K6E PFV 4031 5936 7988 R 404A M1 1 5 3 8 1 1 8 18 208 230 60 1 MHLZ007TB CF06K6E PFV CF06K6E PFV 4270 6437 8832 R 404A S 1 5 3 8 1 1 8 20 208 230 60 1 MHLZ0091B CF09K6E PFV CF09K6E PFV 619...

Страница 39: ...8076 30475 R 404a M3 3 5 8 7 8 26 200 230 60 3 MSHZ0351B ZB26KCE PFV ZB26KCE PFV 24911 29464 32205 34892 R 404a M3 4 5 8 1 1 8 39 200 230 60 1 MSHZ0351C ZB26KCE TF5 ZB26KCE TF5 24823 29294 32038 34727...

Страница 40: ...5 16 Rev B 57 02497 40 UNIT BASE SPECIFICATIONS...

Страница 41: ...5 16 Rev B 57 02497 41 UNIT BASE SPECIFICATIONS CONT...

Страница 42: ...5 16 Rev B 57 02497 42 UNIT BASE SPECIFICATIONS CONT...

Страница 43: ...department at Master Bilt should be contacted at the time of sale or disposal of your walk in so records may be kept of its new location If you sell or give away your Master Bilt cabinet and you evacu...

Страница 44: ...____________________ ____________________________________________________________________________________ Phone _______________________________ Condensing Unit Model_________________________ Serial __...

Страница 45: ...5 16 Rev B 57 02497 45 2015 Master Bilt Products an unincorporated division of Standex International Corporation All rights reserved...

Отзывы: