SP218UXL-19“
41
8.5 Termination
At the end of a DMX512 data cable a 120
Ω
resistor has to be
connected. The SP218UXL does this for input A and input B
automatically as soon as the power is switched on. Optimal wise
one a data line basing on the RS485 interface standard also should
have a termination at the beginning. For this reason the SP218UXL
has a 120
Ω
resistance for every output. This resistor may be
deactivated separately for every output by the jumpers J6 to J13.
By opening the jumpers the signal level can be increased when
required.
8.6 Plug connector assignment Input A for two universes
Connector IN A is equipped for two DMX512 universes with one
cable and has the following pin assignment:
XLR5
RJ45
Data1 + 3
1
Data1 - 2
2
Ground1 1
7 = Ground 2 at XLR5
Data2 + 5
3
Data2 - 4
6
Ground2 1
8 RJ45 separate Ground only
8.7 Plug connector assignment XLR/RJ45
As indicated in DMX512A and ESTA E1.11, the following pinning
have come to the application.
Function XLR 5pol XLR3pol
RJ45/color
Data 1+
3
3
1 wht/orn
Data 1-
2
2
2 orn
Signal ground 1
1
1
7 wht/ brn
Data 2+
5*
-
3 wht/ grn
Data 2-
4*
-
6 grn
Signal ground 2
-*
-
8 brn
not used
4 blu
not used
5 wht/blu