STACKER 500KS USER GUIDE 19
Press the
button in the manual control tab in
STACKER RUN
.
Only home the Y axis!
Now
that the heads are all the way to the front of the bed. Now, place head 2 in the center front of the
bed. As before, use the setup block while adjusting the leveling screw so that the nozzle makes
slight contact with the block.
Step 6. Move the gantry back to the rear and readjust if necessary
. Repeat the leveling process
in Step 4, but you should only need very small adjustments, if at all.
Step 7. Final check and adjustment with setup block.
You must now rehome the zaxis on your
setup block and retest the levelness. Fine adjust, if necessary. Use the same procedures as steps 5
and 6 above. IMPORTANT! If you need to adjust the gap between the now level bed and the
nozzles you need to adjust the zprobe mounting bracket up or down accordingly. See above.
Step 8. Final check and adjustment with business card, a 0.07” feeler gauge, or 0.20mm
feeler gauge.
You must now rehome the zaxis without the setup block. Use a business card or
feeler gauge to check the gap between your bed and nozzles.
IMPORTANT: to dial in the perfect layer height, simply turn the adjustment screw on the
zprobe and rehome the zaxis. See section 5.7 First Print for more details.