14
Appendix
Stabila LD 500
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
Press this button to use a result from the summary line for further
calculations.
Pressing the
and
buttons at the same time erases all the values
in historical storage.
Timer (self-triggering)
Press once briefly to set the delay time using the menu.
or
Press and hold down this button until the desired time delay is
reached (max. 60 seconds).
Once the key is released with the laser activated, the remaining seconds
until measurement (e.g. 59, 58, 57...) are displayed in a countdown. The last
5 seconds are counted down with a beep. After the last beep the measu-
rement is taken and the value is displayed.
)
The timer can be used for all measurements.
Appendix
Message codes
All message codes are displayed with either
or "Error". The following
errors can be corrected:
Cause
Remedy
156
Transverse tilt greater than 10° Hold the instrument without
any transverse tilt
160
Main tilt direction, angle too
high (> 45°)
Measure angle up to max. ± 45°
162
The calibration has not been
accomplished on a leveled
surface and the calibration value
is respecitvely within an ineli-
gible area.
Calibrate the device on an abso-
lute horizontal leveled surface.
204
Calculation error
Repeat procedure
252
Temperature too high
Cool down instrument
253
Temperature too low
Warm up instrument
255
Receiver signal too weak,
measurement time too long,
distance > 100 m
Use target plate
256
Received signal too strong
Target too reflective (use target
plate)
257
Wrong measurement, back-
ground brightness too high
Darken target (measure in diffe-
rent lighting conditions)
260
Laser beam interrupted
Repeat measurement
Error
Cause
Remedy
Error Hardware error
Switch on/off the device several
times. If the symbol still appears,
then your instrument is defec-
tive. Please call your dealer for
assistance.