Wiring the IntelliPro
®
Pump
To connect the IntelliPro
®
pump to an AC power source:
1. Make sure all electrical breakers and switches are turned off before wiring motor.
2. Make sure that the wiring voltage is 230 VAC ± 10%.
3. Use #12 AWG for wire runs up to 100 feet (30.5 meters)and #10 AWG for lengths longer than
100 feet (30.5 meters). When in doubt use a heavier gauge (larger diameter) wire. Heavier gauge
will allow the motor to run cooler and more effi cient.
4. Make sure all electrical connections are clean and tight.
5. Cut the wires to the appropriate length so they do not overlap or touch when connected.
6. Permanently ground the motor using the green ground wire, as shown below. Use the correct
wire size and type specifi ed by National Electrical Code. Make sure the ground wire is connected
to an electrical service ground.
7. Bond the motor to the pool structure in accordance with the National Electrical Code. UL requires
use of a solid copper bonding conductor not smaller than 8 AWG. Run a wire from the external
bonding lug to the pool bonding structure, as shown below.
8. Connect the wire from the accessible wire connector on the motor to all metal parts of the swimming
pool, spa, or hot tub structure and to all electrical equipment, metal conduit, and metal piping within
5 feet of the inside walls of the swimming pool, spa, or hot tub. For Canada, a 6 AWG or larger solid
copper bonding conductor is required.
9. The pump should be permanently connected to either a
circuit breaker
,
2-pole timer
or
2-pole
relay
. If AC power is supplied by a GFCI circuit breaker, use a dedicated circuit breaker that has no
other electrical loads.
10.
IMPORTANT: When connecting the pump to an automation system ( IntelliTouch, EasyTouch,
SunTouch and IntelliComm), continuous power must be supplied to the pump by connecting it
directly to the circuit breaker. When using an automation system, be sure that no other lights
or appliances are on the same circuit.
NOTE: When the IntelliPro
®
is started and stopped by removing power with a relay or timer,
a two-pole device should be used to apply and remove power to both POWER LINE TERMINALS.
30
IntelliPro
®
Variable Speed Pump Installation and User’s Guide
Bonding Lug