AntiFreeze
This feature allows you to set a speed (450 RPM -3450 RPM) that will run when the pump goes into
anti freeze mode. The temperature level that you wish anti freeze mode to start can also be set.
IMPORTANT NOTE: This feature is for protection of the pump. It should not be depended upon for
freeze protection of the pool. Certain situations could cause the pump to sense a different temperature
than actual air temperature. The air temperature sensor on the automation system should be used to
sense actual temperature. For example, if the pump is located indoors, the temperature of the room does
not indicate the outdoor temperature. The pump does not sense the water temperature.
To access the Anti Freeze menu:
1. Check that the green power LED is on.
2. Press the
Menu
button. “Settings” is displayed.
3. Use the
Down
arrow button to scroll to “AntiFreeze”.
4. Press the
Select
button. The factory default is AntiFreeze “Enabled“.
5. To disable AntiFreeze. Press the
Select
button, “Enabled” will highlight.
6. Use the
Up
arrow button. “Disabled” is displayed.
7. Press the
Enter
button.
To program AntiFreeze when enabled:
8. Press the
Down
arrow button.
“Set Speed” is displayed. The factory default is 1000 RPM.
9. Press the
Select
button to change the setting. The cursor will highlight the fi rst column
(ones).
10. Use the
Up
or
Down
arrow button to select 450 - 3450 RPM.
11. Press the
Enter
button to save the setting.
12. Press the
Down
arrow button. “Pump Temperature” is displayed.
This is the temperature the
pump will activate AntiFreeze. The factory default is 40° F (4.4° C).
13. Press the
Select
button to change the setting. The cursor will highlight the fi rst column
(ones).
This setting can be changed from 40° F to 50° F (4.4° C - 10° C).
14. Press the
Enter
button to save the setting. Note: To cancel any changes, press the
Escape
button to exit without saving.
15. Press the
Escape
button to exit.
To
disable the priming feature
on the pump
and let automation system control the pump:
1. Open the lid on the LCD screen of the pump.
2. Verify the green power LED is on. Press the
MENU
button. Settings is displayed.
3. Use
the
DOWN arrow
button to scroll to “Priming”.
4. Press
the
Select
button. The factory default is set to priming “Enabled”.
5. Press
the
UP arrow
button until “Disabled” is displayed.
6. Press
the
Enter
button.
7. Press
the
Escape
button to save and exit the pump menu.
IntelliPro
®
Variable Speed Pump Installation and User’s Guide
19