4
SPECIFICATIONS/DIMENSIONS
23.08
10.12
8.00
4.00
4.25
17.08
7.00
10.69
11.50
1-1/2" NPT
Suction
Ø6.81
8.36
(586)
(257)
(102)
(203)
(434)
(178)
(272)
(292)
(Ø173)
(212)
(108)
1-1/2" NPT
Discharge Port
Union Connection
13.09
(333)
7.47
(190)
8.31
(211)
15.31
(389)
4.50
(114)
6.09
(155)
781 0294
Figure 1: Dimensions
T
able I – Recommended Circuit Breaker Size for 115V 60 Hz Motors
Branch
Model
Motor
Voltage/
Full Load
Circuit Breaker
No.
H.P.
Hz/Phase
Amps
Rating(Amps)
Single Speed:
JWPA5DC-2A3U
3/4
115/60/1
9.4
15
JWPA5EC-2A3U
1
115/60/1
11.9
15
17290-J150
1-1/2
115/60/1
13.5
20
JWPS5FC-2A3U
1-1/2SPL
115/60/1
11.9
15
Dual Speed:
17290-J1002
1
115/60/1
11.0/2.9
15
JWPA5YEL-4A3
1
115/60/1
11.0/2.9
15
JWPS5YFL-4A3
1-1/2SPL
115/60/1
11.0/2.9
15
NOTICE:
Values given in table above are for pump motor only. Add the amp
draw for any additional accessories installed on pump motor circuit (heater,
blower, etc.) to the listed amp ratings when figuring circuit and circuit breaker
requirements.