background image

INSTALLATION

Install the pump as a free standing unit or with a guide rail
lift-out system.

Free-Standing Unit:

Install the pump on the floor of an open top basin. Install a
pipe union in the discharge piping, so that the pump can be
lifted out of the basin without interference.

Lift-out System 

(see Assembly Steps, Page 4)

:

(See Figures 4 and 5 before assembling)
1.

Mount the base flange (See Step 1, Page 4) to the basin
floor.

2.

Thread the 2-1/2” (64 mm) dia. pipe section (Step 2) into
the base flange and tighten it.

3.

Install the stationary flange (Step 3) on the base pipe
and tighten the set screw to hold it.

4.

Install the connecting plumbing in the stationary flange
(Step 4).

5.

Thread the user supplied 1” (25 mm) dia. guide rails
(Step 5) into the stationary flange and tighten them.

6.

Mount the upper rail bracket on the angle bracket
(Step 6).

7.

Install the angle bracket and upper rail bracket assembly
in the tank or attach it to the basin lid as desired 
(Step 7).

8

.

Install the basin lid now if the guide rail bracket is
mounted on it (Step 

8

).

The stationary parts (all those parts mounted in the basin)
of the guide-rail lift-out system are now complete. Go on to
Step 9 to assemble the movable parts of the system. These
will mount on the pump discharge assembly.

Follow the

sequence below that applies to your pump model.

SG12 / SG13 Series:

9A.

SG12/SGC12/SG13/SGC13

Thread the 1-1/4x

8

-1/2” nipple

into the pump discharge and tighten it.

9B.

SG12/SGC12/SG13/SGC13

Install the movable guide rail

bracket over the 

8

-1/4” nipple, then install one half of the

pipe union on top of the nipple and tighten it. Do not tight-
en the set screws in  the guide rail bracket yet.

9C.

SG12/SGC12/SG13/SGC13

Clamp the ball check valve

upside down (that is, flange up) in a vise so that it can-
not turn (or fall) and thread one of the short nipples into
it. Install the unused union half on the short nipple and
tighten the assembly.

9D.

SG12/SGC12/SG13/SGC13

Turn the check valve

assembly over in the vise; clamp it so that the ball
chamber points to your right or your left. Install the other
short nipple in the discharge (hex) end of the check
valve. Add the discharge pipe bracket over the nipple
and then thread the movable flange onto the nipple.
When tight, the movable flange should point directly
away from you (that is, the check valve and the flange
should be at right angles to each other). Install two 
O-Rings on the movable flange (see Step 9, Page 4).

10.

SG12/SGC12/SG13/SGC13

Remove the check valve

assembly from the vise and turn it over; connect the
union and tighten it with the movable flange pointing
directly away from the pump. The ball check should point
to one side or the other while the movable bracket points
away from the pump. Thread the eyebolt through the dis-
charge pipe bracket into the tapped hole provided in the
top of the pump.

11.

SG12/SGC12/SG13/SGC13

Thread the locking rail into

the movable flange; mount the locking bracket and tight-
en.

The movable parts of the SG12/SGC12/SG13/SGC13
system are now complete. You are ready to rig lifting gear
and lower the pump into the basin. Skip to Step 12.

SG20 Series:

9A.

SGC20

Thread one of the short nipples into the pump

discharge; add a union half and tighten the assembly.

9B.

SGC20

Clamp the ball check valve in a vise; thread the

2x6” nipple into the inlet side. Slide the guide rail bracket
(also upside down) on to the nipple and thread the other
union half over the free end of the nipple. Tighten.

9C.

SGC20

Turn the assembly over in the vise and thread

the other short nipple onto the discharge side of the ball
check valve. Add the discharge pipe bracket and the
movable flange to this nipple and tighten the assembly.
When tight, the ball check should point to one side or
the other and the movable flange should point directly
away from you (that is, the check valve and the flange
should be at right angles to each other). Install two 
O-Rings on the movable flange (see Step 9, Page 4).

10.

SGC20

Mount the ball check valve/discharge flange

assembly on the pump with the movable flange pointing
directly away from the pump. Tighten the union and
thread the eyebolt through the discharge pipe bracket
into the the threaded hole provided in the top of the
pump.

11.

SGC20

Thread the locking rail into the movable flange;

mount the locking bracket and tighten.

The movable parts of the SGC20 system are now complete.
You are ready to rig lifting gear and lower the pump into the
basin.

12. Lift the pump assembly; slide the guide rail bracket and

the movable flange over the guide rails at the top and
lower the pump into the basin until it bottoms on the sta-
tionary flange. Raise the pump 1/

8

” and tighten the

guide rail bracket set screws.

13. Slide the locking bracket over the guide rails and locking

rail, then tighten all three set screws.

14.

To remove the pump

, loosen the guide rail set screws

in the locking bracket and hoist the pump out of the
basin.

CONTROLS

Risk of electric shock. Ground pump and

motor before connecting controls or power supply.

Adhere to local electrical codes governing pump and control
installations.
Install simplex or duplex control panel for proper pump oper-
ation. A full range of controls and switches is listed in our
catalog.
If a Sta-Rite control panel is not used, install a control panel
with circuit breaker or fused disconnect as required by local
code. Use magnetic starters with ambient compensated
overload protection. Three phase units require three line pro-
tection; single phase units require only one line protection.
Inadequate protection voids warranty.

SGC12/SGC13

Series pumps are equipped with an on-

winding thermostat (to protect the pump from overheating)
and seal leak detection probe (to monitor seal plate and
motor housing for the presence of water).

5

Содержание 12SG1-1011

Страница 1: ...is pumping domestic sewage and waste water containing solids Do not pump metal particles rocks or other hard objects 7 Do not pump corrosive or flammable liquids with this pump DESCRIPTION These subm...

Страница 2: ...cm Minimum Basin Diameter Simplex 24 61 cm Minimum Basin Diameter Duplex 36 91 cm Dimension SGC20 Vertical Discharge Pipe Length Disch Pipe Height X X 25 7 16 64 5cm Locking Rail Length Basin Depth Y...

Страница 3: ...066 8 46 1168 4 62 15 7 17 431 8 18 457 2 16 406 4 7 37 187 1 22 88 581 Simplex 48 1219 2 54 1371 6 2 92 74 1 17 431 8 21 533 4 16 406 4 9 67 245 6 22 88 581 60 1524 66 1676 4 2 92 74 1 17 431 8 27 68...

Страница 4: ...SGC12 and SG13 SGC13 This difference is required by the difference in size between the two pumps Make sure that you use the correct sequence for your pump or the piping assembly will not mount on the...

Страница 5: ...the tapped hole provided in the top of the pump 11 SG12 SGC12 SG13 SGC13 Thread the locking rail into the movable flange mount the locking bracket and tight en The movable parts of the SG12 SGC12 SG1...

Страница 6: ...1 T1 T4 T5 T8 L2 P2 Ground Green Power Cable 14 4 Black Common White Main Red Start Black White Red T1 T1 T1 T1 T4 T4 T4 T5 T6 T7 T7 T7 T8 T8 T8 T5 T5 T2 T6 T2 T2 T9 T9 T6 T6 T5 T8 T3 T3 T3 T3 Leak Se...

Страница 7: ...ing inside a stationary cutter ring Persistent jamming and clogging of the pump indicates dull or worn grinder parts If the cutter ring is dull reverse it to renew the cutting edges If the cutter ring...

Страница 8: ...l new O Rings and seals during re assembly 1 Press a new ceramic seal head into place in the seal plate Be sure that you do not damage the seal face when sliding it over the shaft shoulder 2 Clean out...

Страница 9: ...For Series For Series SG12 SGC12 SG13 Key SGC13 SGC20 No Part Description W52439L W52440L 9 Base Pipe W52435 W52433F 10 Stationary Flange W52285 W52287 11 O Ring 22302 2 22302 2 12 Movable Flange W52...

Страница 10: ...10 13 14 15 16 17 18 19 20 22 23 27 24 25 26 22 31 32 33 34 35 36 28 29 30 1 2 1 10 2 3 4 7 8 1 12 11 21 1944 0895...

Страница 11: ...4 16504 23 Retaining Ring 1 25395 25395 24 O Ring 1 25379 25379 25 Back Plate SG12 SGC12 Series 1 W52023 W52023 25 Back Plate SG13 SGC13 Series 1 W52033 W52033 26 1 4 20x3 4 Socket Head Cap Screw SS 3...

Страница 12: ...12 12 13 15 16 14 17 18 19 1 4 5 6 7 8 9 11 10 21 20 22 22 23 24 25 26 28 32 29 30 31 34 35 36 27 1 1 2 2 9 5 7 8 6 1 2 3 4 37 1945 0895...

Страница 13: ...2039 W52037 W52039 W52163 29 Cutter 1 W52259 W52259 W52259 W52259 W52259 30 Impeller Retainer 1 W52093 W52093 W52093 W52093 W52093 31 3 8 16x1 Socket Hd Cap Screw SS 1 10672 10672 10672 10672 10672 32...

Страница 14: ...ase motors must be protected by three leg ambient compensated extra quick trip overload relays of the recommended size or the warranty is void Your only remedy and STA RITE s only duty is that STA RIT...

Страница 15: ...pompe ad quatement entretenue 6 N utiliser la pompe qu aux fins pour lesquelles elle est pr vue c est dire le pompage des eaux d gout et des eaux us es domestiques contenant des mati res solides Ne pa...

Страница 16: ...n simplex 24 po 61 cm Diam tre minimum du bassin duplex 36 po 91 cm Dimensions SGC20 Longueur verticale du tuyau de refoulement Hauteur du tuyau de refoulement X X 25 7 16 po 64 5cm Longueur de la gli...

Страница 17: ...67 245 6 22 88 581 SGC20 48 1219 2 54 1371 6 2 69 68 3 22 558 8 21 533 4 32 812 8 9 228 6 6 56 166 6 24 88 632 Duplex 60 1524 66 1676 4 2 70 68 22 558 8 27 685 8 20 508 9 228 6 11 95 303 5 24 88 632 S...

Страница 18: ...les SG12 SGC12 et SG13 SGC13 Cette dif f rence est requise tant donn que les dimensions de ces deux pompes sont dif f rentes S assurer de suivre le bon ordre de mon tage en fonction de la pompe sinon...

Страница 19: ...effet en haut de la pompe 11 SG12 SGC12 SG13 SGC13 Glisser la glissi re de blocage dans la bride mobile poser le support de blocage et le serrer Les pi ces mobiles du syst me pour les s ries SG12 SGC1...

Страница 20: ...ontre les surcharges doit tre utilis sur les moteurs monophas s si un pan neau de commande Sta Rite n est pas install Se reporter au Sta Rite pour acheter cet ensemble Figure 6 Connexions lectriques d...

Страница 21: ...Le broyeur de cette pompe se compose d un couteau tournant l int rieur d une couronne de broyage Un coincement et un blocage constant de la pompe indiquent que les pi ces du broyeur sont mouss es ou...

Страница 22: ...s lors du remontage 1 Pousser la t te d un joint en c ramique neuf en place dans la plaque d tanch it Faire bien attention de ne pas endom mager la face du joint d tanch it lorsque l on glisse le join...

Страница 23: ...2 1 2 13352 2 8 Bride de base S11787 S11787 9 Tuyau de base W52435 W52433F 10 Bride fixe W52285 W52287 11 Joint torique 22302 2 22302 2 12 Bride mobile W52289 W52290 13 Barre de blocage W52293 W52293...

Страница 24: ...10 13 14 15 16 17 18 19 20 22 23 27 24 25 26 22 31 32 33 34 35 36 28 29 30 1 2 1 10 2 3 4 7 8 1 12 11 21 1944 0895...

Страница 25: ...arr t 1 25395 25395 24 Joint torique 1 25379 25379 25 Plaque d appui S ries SG12 et SGC12 1 W52023 W52023 25 Plaque d appui S ries SG13 et SGC13 1 W52033 W52033 26 Vis chapeau t te creuse en acier ino...

Страница 26: ...12 12 13 15 16 14 17 18 19 1 4 5 6 7 8 9 11 10 21 20 22 22 23 24 25 26 28 32 29 30 31 34 35 36 27 1 1 2 2 9 5 7 8 6 1 2 3 4 37 1945 0895...

Страница 27: ...037 W52039 W52163 29 Couteau 1 W52259 W52259 W52259 W52259 W52259 30 Support du couteau 1 W52093 W52093 W52093 W52093 W52093 31 Vis chapeau t te plate en acier inoxydable de 3 8 16 x 1 po 1 10672 1067...

Страница 28: ...de surcharge tripolaire thermocompens d clenchement extr mement rapide du calibre recommand sinon la garantie sera nulle et non avenue Le seul recours de l Acheteur et la seule responsabilit de STA R...

Отзывы: