Ashby-P Insert
33
Changing the program on the Control Board
To change the Program the Insert must be in the OFF
position, the unit must be completely cooled down so
the Proof of Fire Switch is Open and the Thermostat
slide switch must be in the Manual mode.
(See figure
19)
Press & hold
the Auger Feed Button, then press the
Trim
High & Low
Button at the same time. The LED
lights that indicate the heat level will flash. The
number of times the lights Flash will indicate which
program is running.
Program 1 – LED lights flash
once
Program 2 – LED lights flash
twice
Program 3 –LED lights flash
three times
Program 4 – LED lights flash
four times
Figure 19
Lighting Your Ashby-P with the Versa Grate System. (Program 3 & 4)
1. Make sure there are pellets in the hopper and the viewing door and ash pan door are
closed.
2. Push the On/Off button on the control board. (
See figure 19 on page 34)
At this point all that needs to be done is to monitor the burn pot to make sure the stove
starts up properly. Once the On/Off button has been pushed the Start Up program takes
over.
The Start up Program works as follows:
a.
The Combustion fan and Room fan come on at high speed and the control board
checks to make sure the Vacuum switch locks in. (See Diagnostic features on
page 34 and 35