Single Gas Analyzer (SGA)
Operations Manual
Super Systems Inc.
Page 26 of 44
Page 26 of 51
Output Configuration
The Output Configuration screen allows you to adjust output parameters for loops 1 and 2.
For each loop, the following parameters can be adjusted:
Source: A selected source: External or NDIR Gas.
Zero (%): The % output at the lowest end of the applicable range.
Span (%): The % output at the highest end of the applicable range.
Range: The output mode: 4-20 mA or 0-20 mA.
Manual (%): A %Output entered manually.
Use the applicable “Set” button to set each parameter (for example, use “Set Source” to set the
source).