SSI PRL-1600 Скачать руководство пользователя страница 14

SOLID STATE INSTRUMENTS

INSTRUCTION SHEET

PRR-16 PULSE RECEIVER BASE UNIT

Revision: 4/3/22

OUTPUT CONFIGURATION -

 The PRR-16 contains four solid state Form A dry-contact outputs, two each for

both "K", "Y" and "Z" outputs.  Each solid state output is limited to 100mA@ 250VAC, 800mW maximum.  Fuses
are sized at 1/10th amp (100mA).  Do not exceed this rating as the device will be destroyed.  Transient voltage
protection for the contacts of the solid state relays are provided by MOVs on board.

a division of Brayden Automation Corp.

6230 Aviation Circle, Loveland, Colorado 80538

Phone: (970)461-9600

E-mail:[email protected]

RSSI SIGNAL STRENGTH INDICATOR - 

The PRR-16 contains a 3-LED bar graph that tells the relative signal

strength coming from the Transmitter. It consists of three RED LEDs in the upper left-hand corner of the board.

14

GND

K
Y

Z

NEU
120V

OUTPUT #1

POWER SUPPLY
INPUT

STATUS LEDS -

 The PRR-16 has four status LEDs to indicate the status of the system at all times.  See Page

__ for description of the Status LED functions.

POWER INPUT -

 For a power supply of 120 VAC, use the the 

L1

 terminal for the "hot" lead.  For 208 to 277

volts AC, use the 

L2

 terminal for the "hot" lead.  Connect the Neutral lead to the 

NEU

 terminal. Connect the 

GND

terminal to Ground.  GROUND MUST BE CONNECTED TO A GOOD ELECTRICAL SYSTEM GROUND!!!

SIGNAL INPUT -

 The PRNR-1600 receiver/antenna unit connects to the 9-position connector labelled TB2.

Terminals are numbered in the same order on the PRNR-1600 and the PRR-16.  Connect #24AWG 8-conductor
(4-twisted pairs) shielded control cable between the PRNR-1600 receiver/antenna board and the PRR-16
making sure that all connections are matched up on both ends: 1 to 1; 2 to 2; etc.  Make sure that the control
cable's shield is connected to position 9 on each end.

277V

From PRNR-1600

Receiver/Antenna Unit

L2

L1

N

G

Z2

Y2

K2

1

2

3

4

5

6

7

8

9

K
Y

Z

Z1

Y2

K1

OUTPUT #2

GENERAL -

 The PRR-16 serves as a base unit, and termination

point for the PRNR-1600 receiver radio/antenna unit.  It contains
a power supply, output relays and all connection points for the
receiver/antenna unit.

SCK-

SDI+

SDI-

SCK+

+V

GND

BR/W

BRN

OR/W

GR/W

GRN

SHLD

SDO+

SDO-

ORG

BL/W

BLU

SLVR

TB2

TB1

24AWG (min)/8-conductor (4-twisted
pair) with shield 100' max.

ENCLOSURE -

 The PRR-16 base unit is mounted on a aluminum base and is designed to be mounted into

another electrical enclosure suitable for the application.  Optional NEMA 3R and 4X raintight enclosures are
available.

Lo

w

 (

F

a

ir

)

Med (Good)

High (Ex

c

e

ll

e

n

t)

PRR-16

Receiver

Base Unit

(Not to Scale)

1

2

3

4

RSSI

Learn S

ta

tu

s

D

IP

 T

ra

n

sfer

Data Transfe

r

Heartbea

t

STATUS LEDs

Содержание PRL-1600

Страница 1: ...s Pulse Link System Technical Manual Solid State Instruments A division of Brayden Automation Corporation 6230 Aviation Circle Loveland CO USA 80538 970 461 9600 e mail support brayden com Revision A1...

Страница 2: ...roduction PRNT 1600 Pulse Radio Transmitter PRT 16 Transmitter Base Unit Using the 2 Wire Form A or 3 Wire Form C Modes PRNR 1600 Pulse Radio Receiver PRR 16 Receiver Base Unit Troubleshooting and Tec...

Страница 3: ...cycle The Receiver will then generate the correct number of pulses at KYZ outputs over the next 10 seconds The PRNT 1600 Transmitter Antenna Unit contains the transceiver radio a microcontroller and a...

Страница 4: ...n one of the channel frequencies until they are received by the receiver Set the Transmitter and the Receiver to the same channel number Multiple PRL 1600 systems can operate in the same radio airspac...

Страница 5: ...cars trucks buses or any other obstruction that gets in the line of sight between the transmitter and receiver at any time Interruptions in the line of sight may cause pulses to be lost Generally spe...

Страница 6: ...ctors being careful not to cut the insulation of the conductors or any strands of the shield s drain wire Strip the insulation of each conductor back 1 4 Connect each conductor of the cable to the 9 p...

Страница 7: ...Scale 8 Conductor 4 Twisted Pairs 24AWG Control Cable with shield 100 max POWER INPUT The PRNT 1600 receives its power supply from the PRT 16 Transmitter Base unit NOTICE TO USER FCC ID TIT PRT 1600 T...

Страница 8: ...2 3 4 5 6 7 8 9 TB1 Transmitter Antenna PCB Assembly LED1 PRNT 1600 Wire Connection Assignments 1 3 2 4 6 5 7 8 9 Terminal Pair 1B 2A 2B 3A 3B 1A 4A 4B ORG WHT ORG GRN WHT BLU WHT BLU GRN BRN WHT SILV...

Страница 9: ...e K common and a Y input Four independent 2 Wire meter pulse channels can be transmitted Set Switch 7 to the DOWN position for the Form A mode and UP for Form C mode Switch 8 Pairing the Transmitter a...

Страница 10: ...meter 277V Revision 4 10 22 To PRNT 1600 Transmitter Radio Antenna Unit L2 L1 N G Kin Y1in Z1in INPUT CONFIGURATION The PRT 16 accepts either 2 Form C 3 Wire inputs using the K Y Z input terminals or...

Страница 11: ...he conductors or any strands of the shield s drain wire Strip the insulation of each conductor back 1 4 Connect each conductor of the cable to the 9 position connector TB1 using a small flat blade scr...

Страница 12: ...harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or...

Страница 13: ...ch 4 Not used Switch 5 Fixed Pulse Width Sets the output pulse width to 50mS DOWN or 100mS UP when in Form A mode Switch 6 Not used RSSI Indicator The receiver has an Signal Strength Indicator to show...

Страница 14: ...o the NEU terminal Connect the GND terminal to Ground GROUND MUST BE CONNECTED TO A GOOD ELECTRICAL SYSTEM GROUND SIGNAL INPUT The PRNR 1600 receiver antenna unit connects to the 9 position connector...

Страница 15: ...2 3 4 5 6 7 8 9 TB1 Transmitter Antenna PCB Assembly LED1 Wire Connection Assignments 1 3 2 4 6 5 7 8 9 Terminal Pair 1B 2A 2B 3A 3B 1A 4A 4B ORG WHT ORG GRN WHT BLU WHT BLU GRN BRN WHT SILVER BRN BR...

Страница 16: ...ving downstream device or by an auxiliary power supply The outputs are solid state and are non polarized They may be used for AC or DC voltages The output is limited to 100mA 250VAC 800mW maximum Fuse...

Страница 17: ...r the transmitter and receiver respectively 2 Set Dip Switch 8 on both the transmitter and receiver to the UP position to put the system in the Learn mode 3 Turn on power to the PRR 1600 Receiver The...

Страница 18: ...r to the transmitter s input Set both the transmitter and receiver to Form C by setting Dip Switch 6 to the UP position Using two wires K and Y on a Form C output is acceptable 2 Dip Switch 8 must be...

Страница 19: ...THING 3 Mount the Transmitter or Receiver Radio Antenna units as high up off the ground as reasonably possible to prevent RF reflections from the ground This will increase range and reliability and al...

Страница 20: ...ly to all components Check the RED LED on the Transmitter and Receiver Antenna boards and make sure they are flashing in fast mode Check to make sure that all Transmitter and Receiver units are both o...

Страница 21: ...Appendix A PRT 1600 Dip Switch Settings and LED Indicators 21...

Страница 22: ...Appendix B PRR 1600 Dip Switch Settings and LED Indicators 22...

Страница 23: ...r there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turn...

Отзывы: