DIGIVEX Little Drive Servoamplifier
82
PVD 3530 GB 01/2005
DEFAULT
TYPE
ACTION
7
Excessive mean
or
rms
current
Mean current: measurement of the mean current supplied by the motion controller
Rms current: calculation of the rms current supplied by the motion controller
Causes:
•
Oversized operating cycle
•
Mechanical binding spot
8
Bus overvoltage
Braking recovery impossible
Causes:
•
Oversized operating cycle
•
Motion controller braking capacity much too low with regard to the application
9
Excessive
motor
temperature
Causes:
•
Check connections
•
The motor is confined and cannot cool down
•
Motor does not have a temperature sensor: this sensor was not acknowledged during
customization.
r
Recovery fault
Causes:
•
Cycle too restricting
•
Axis recovery capacity exceeded.