4.5.2 Motor end connection
Power connection
There are two possibilities for connection:
Terminal block + resolver connector.
Power con resolver connector.
Terminal block connection
For the terminal block, the clamping nuts and washer come in a bag
Take care when fitting the lugs not to loosen the connecting leads between the motor and the
terminal block.
The power connection lugs are to be inserted between
the striated washer and the flat washer.
Digpl3.D
Motor direction of rotation:
by wiring as recommended, a positive set point applied to the drive
entails clockwise rotation (viewed from the power shaft end).
cable
≥
1mm²
cable
≥
1mm²
W
V
U
1
2
3
4
ALIMENTATION/SUPPLY/SPEISUNG
FREIN/BRAKE
BREMSE
U Phase U
V Phase V
W Phase W
1 Optional brake
+24 V
2 Optional brake
0 V
3 Thermal sensor
4 Thermal sensor
Thermal