15
Pull lever back to setting “30” on gauge and lever assembly. Next push pivot & bracket forward so that the shut off
plate in the hopper is in the full open position.
REMEMBER SETTING “30” ON THE FLOW CONTROL LEVER MUST PLACE THE SHUT-OFF PLATE IN THE FULL OPEN
POSITION TO BE PROPERLY CALIBRATED. Now tighten the nuts against the PIVOT BRACKET to prevent change in
calibration.
16
17
Tension on the flow control LEVER may be
adjusted by tightening or loosening the
tension nut on gauge and lever assembly.
Insert agitator into pinion shaft on inside
of hopper.
NOTE: the position of flat side of the agita
-
tor in the drawing. The agitator should be
installed as shown.