background image

AY-x6255 Family 

CSN SELECT Smart Card Readers 

Installation and User Manual

 

1.

 

Introduction 

The AY-x6255 is a family of multi-format contactless smart card 

readers for use in access control system solutions. 
CSN SELECT readers support reading from the secure memory of the 

following credential technologies: 

 

MIFARE Ultralight / Ultralight C 

 

MIFARE Classic 

 

MIFARE Plus S / Plus X 

 

MIFARE DESFire EV1 

 

ISO 14443A 

 

ISO 14443B 

 

ISO 15693 

 

iClass 

 

ISO 18092 (NFCIP-1) 

 

FeliCa 

1.1

 

Box Content 

Before beginning, verify that all of the following is in the box. If 
anything is missing, please report the discrepancy to your nearest 

Rosslare office. 

 

One AY-x6255 unit 

 

Installation kit – Includes two wall plugs, two mounting screws, 

security Torx screw, and security Torx screw tool 

 

Installation and operating instructions 

 

 

 

 

AY-K6255 

AY-L6255 

AY-H6255 

AY-M6255 

2.

 

Technical Specifications 

2.1

 

Electrical Characteristics 

Power Supply Type 

Linear (recommended) 

Operating Voltage Range 

8 to 16 VDC 

Current @ 12 V 

Standby: 100 mA 
Maximum: 120 mA 

Read Range* 

MIFARE Classic EV1: 40 to 45 mm (1.5 to 1.8 in.) 
MIFARE Plus: 30 mm (1.2 in.) 
MIFARE DESFire EV1: 30 mm (1.2 in.) 

LED Control Input 1** 

Green LED control, TTL 

LED Control Input 2** 

Red LED control, TTL 

Auxiliary Input** 

Buzzer control, TTL 

Auxiliary Output** 

Tamper output (open collector, active low, max. 

sink current 30 mA) 

Maximum Cable Distance 
to Controller 

Wiegand: 150 m (500 ft) with 18-AWG cable 
OSDP (RS-485): 1200 m (4,000 ft) with 2x2 18-

AWG twisted shielded cable 

*  Measured using a Rosslare MIFARE card cards. Range also depends on 

electrical environment and proximity to metal. 

** Standard configuration. Custom configurations are available

2.2

 

Environmental Characteristics 

Operating Temp. Range 

-25°C to 65°C (-13°F to 149°F) 

Operating Humidity Range 

0 to 95% (non-condensing) 

Outdoor Usage 

Weather-resistant, UV-resistant, meets IP65, 

epoxy-potted, suitable for indoor and outdoor 
use 

2.3

 

Physical Characteristics 

Dimensions 
(H x W x D) 

AY-K6255: 80.5 x 40.5 x 14.7 mm 
(3.2 x 1.6 x 0.6 in.) 
AY-L6255: 144.9 x 42.9 x 22.1 mm 
(5.7 x 1.7 x 0.9 in.) 
AY-H6255: 110.7 x 75.0 x 17.1 mm 
(4.4 x 3.0 x 0.7 in.) 
AY-M6255: 89.5 x 88.9 x 16.8 mm 
(3.5 x 3.5 x 0.7 in.) 

Weight 

AY-K6255: 77 g (2.7 oz) 
AY-L6255: 126 g (4.4 oz) 
AY-H6255: 163 g (5.7 oz) 
AY-M6255: 145 g (5.1 oz.) 

3.

 

Wiring Instructions 

The units are supplied with a 10-conductor 18” (46-cm) pigtail or with 
10 terminal blocks. 
To connect a pigtail reader to the controller: 
1.

 

Prepare the reader cable by cutting its jacket back 3.2 cm (1¼”) 

and strip the insulation from the wires 1.3 cm (½"). 

2.

 

Prepare the controller cable by cutting its jacket back 3.2 cm (1¼") 

and strip the insulation from the wires 1.3 cm (½"). 

3.

 

Splice the reader’s pigtail wires to the corresponding controller 

wires (as indicated in Table 1) and cover each joint with insulating 

tape. 

4.

 

If the tamper output is being utilized, connect the purple wire to 

the correct input on the controller. 
The LED control may be configured by the factory to function 

either as a LED control or as buzzer control. Currently, the auxiliary 

input is used as buzzer control and LED Control 1 is used as the 
green LED control. 

5.

 

Trim and cover all unused conductors. 

Table 1: AY-x6255 Wiring 

Wire Color 

Output 

Red 

Power 

Black 

Ground 

Green 

Data 0 / Data 

White 

Data 1 / Clock 

Purple 

Tamper Output 

Orange 

Green LED control 

Brown 

Red LED control 

Yellow 

Buzzer control / Auxiliary input 

Blue 

OSDP-RS-485-A* 

Gray 

OSDP-RS-485-B* 

*H and M models only 

 

 

 

The individual wires from the reader are color coded according the 
Wiegand standard. 

 

When using a separate power supply for the reader, this supply and 
that of the controller must have a common ground. 

 

The reader’s cable shield wire should be preferably attached to an earth 
ground, or a signal ground connection at the panel, or power supply 

end of the cable. 