![SS Telecoms SS-77 uTMS Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/ss-telecoms/ss-77-utms/ss-77-utms_user-manual_1354338028.webp)
SS-77 uTMS USER MANUAL
DOC. NO: SS-77 uTMS (REVISION 08)
Page 28 of 37
COMMAND TABLE
Command
Description
LIP <a.b.c.d>
Sets the local IP address to a.b.c.d This setting is ignored when DHCP
mode is enabled.
SNM <e.f.g.h>
Sets the Subnet Mask to e.f.g.h This setting is ignored of DHCP mode is
enabled.
GWA <i.j.k.l>
Sets the Gateway Address to i.j.k.l This setting is ignored of DHCP mode
is enabled.
DNS <m.n.o.p>
Sets the DNS server address to m.n.o.p This setting is ignored of DHCP
mode is enabled.
NBN <NetBIOS
Name>
This will set the NetBIOS Name. The default name is ‘SS-77-ABCDEF
where the ABCDEF is the last 6 characters of the MAC address. The
name can be set to any alpha-numeric string up to 15 characters long.
UDH <ON/OFF>
Use DHCP or not. Default is ‘ON’. Input can be Y/N, T/F, E/D, 1/0 or
ON/OFF
UTM <ON/OFF>
Set 10Mbit operation. Input can be Y/N, T/F, E/D, 1/0 or ON/OFF. When
this setting is enabled the buffer will only connect at 10Mbit and not
100Mbit. On some LANs auto-negotiation of LAN speed may cause LAN
link issues, so 10Mbit can be manually selected.
STS <time.server>
Sets the address of the timer server. Either FQDN format (time-a.nist.gov)
or dotted IP (129.6.15.28) is suitable. Dotted format will be necessary if no
DNS server is available.
STZ <time offset>
Set the time offset from UTC in minutes. Negative for East, positive for
West. South Africa (the default) is -120.
SDI <date
parameters>
The SDI command is used to enable the insertion of the Date and Time
either before the record or after the record. The command parameters are
either low case to remove an option or upper case to enable an option.
Certain parameters automatically either remove others (you can’t have the
century without the year, so disabling the year disables the century) or
enables them (enabling the century automatically enables the year). The
parameter letters are:
Enable Disable Description
A
a
Insertion AFTER the record data – fixed format
hhmmDDMMCCYY.
B
b
Insertion ‘Before’ the record data, allows some format
options.
C
c
Stores the Century giving a 4 digit year, only for ‘Before’
Y
y
Stores the year as 2 digits, only for ‘Before’
S
s
Stores the seconds, only for ‘Before’
Example:
To set the storage ‘Before, 2 digit year, no seconds’ input: “SDI BacYs”
The various flags can be set or enable individually, so to turn on seconds
use “SDI S”. This will set the seconds on. The result of the command is
displayed.
Содержание SS-77 uTMS
Страница 1: ...SS 77 uTMS User Manual ...