SS-77 uTMS USER MANUAL
DOC. NO: SS-77 uTMS (REVISION 08)
Page 13 of 37
LAN Settings
Use DHCP
Enable this when using DHCP.
Local IP
Sets the local IP address of the Buffer. This setting is ignored
when DHCP mode is enabled.
Subnet
Sets the Subnet Mask to use. This setting is ignored when
DHCP mode is enabled.
Gateway
Sets the Gateway Address to be used. This setting is ignored
when DHCP mode is enabled.
DNS Server
Sets the DNS server address to be used. This setting is ignored
when DHCP mode is enabled.
NetBios Name
This will set the NetBIOS Name. The default name is ‘SS-77-
ABCDEF where the ABCDEF is the last 6 characters of the MAC
address. The name can be set to any alpha-numeric string up to
15 characters long.
MMI Listen Port Sets the port number for the SS-77 that it will listen on for MMI or
NetLog connections via the LAN interface.
Use Link Signal When enabled the buffer checks the physical link in relation to
stopping or starting the LAN functions. When switched ‘OFF’ the
Link Status is ignored and the LAN interface is started up just
using some timing delays.
LAN Speed
Selection between 10Mbit and 100Mbit. On some LANs auto-
negotiation of LAN speed may cause LAN link issues, so 10Mbit
can be manually selected.