SS-77 uTMS USER MANUAL
DOC. NO: SS-77 uTMS (REVISION 08)
Page 16 of 37
9. PROGRAMMING SCENARIOS AND EXAMPLES
9.1. Scenario 1
The client has a PABX that has a serial output for the CDR’s. The PABX baud rate is 9600.
The data will be collected using the NetLog software. Netlog software uses an active TCP LAN
connection on port 23 to collect the data (CDR’s) from the buffer. The IP assigned to the buffer is
192.168.0.234.No date insertion is required.
Scenario 1
This explains how to setup the buffer to log data on the serial port and dump the data via LAN.
Description
Main Screen
Step 1
Connect a serial cable between the buffer serial port 1 and your PC.
Connect a serial cable between the buffer serial port 2 and the PABX.
Connect a LAN cable between the buffer and the network.
Step 2
Select the Com port to be used on the PC.
Step 3
Select Baud Rate 115200
Step 4
Once conneted. The version of the buffer firmware and the buffer status menu will
be displayed on the terminal.
Step 5
Click on Setup. The following screen will be displayed.