![Srne HT4830S80-145 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/srne/ht4830s80-145/ht4830s80-145_user-manual_1354165015.webp)
All-in-one Solar Energy Storage Inverter Controller
15
locations shown below. The PV ports on the machine are preferred for wiring.
PV+:PV input positive
PV-:PV input negative
BAT
wiring method:
Before wiring, disconnect the circuit breaker first, and confirm whether the wires
used are thick enough. Please refer to Section 2.2 Wiring Specifications and Circuit
Breaker Selection . The BAT wires need to be connected to the machine through O-type
terminals. It is recommended to use the O-type terminals with an inner diameter of 6 mm,
and the O-type terminals must be firmly pressed against the BAT wires to prevent
overheating due to excessive contact resistance.
Correctly connect the BAT wires according to the wire sequence and terminal
locations shown below.