All-in-one Solar Energy Storage Inverter Controller
30
Parameter
no.
Parameter
name
Settings
Description
32
Type
of
communication
connection
[
32] SLA
default
Communication Connect to our remote
monitoring module (WiFi, GPRS...)
[
32] BNS
Communication connection battery BMS
[
33] PAC
default
Pace BMS Protocol (valid when parameter
[32] is set to BNS)
[
33] RDA
Ratar BMS Protocol (valid when parameter
[32] is set to BNS)
[
33] AOG
[
33]
XWD
[
33] DA
Q
[
33] WOW
37
Battery fully
charged
recovery point
[
37
]
52V
default
38
AC output
voltage setting
[
38] 230Vac
default
Settable
: (200/208/220/240Vac)
After the battery is fully charged, it needs to be
lower than this set voltage before it can be
recharged
[
33] PYL
33
BMS
protocol type
Allgrand BMS Protocol (valid when parameter
[32] is set to BNS)
Sunwoda BMS Protocol (valid when parameter
[32] is set to BNS)
Dyness BMS Protocol (valid whenparameter
[32] is set to BNS)
Pylontech BMS Protocol (valid when parameter
[32] is set to BNS)
-
35
Battery
lowvoltage
recover
[
35] 50.4V
default
When the battery voltage is under voltage, the
battery voltage needs to recover more than this
set value before the inverter starts the output
36
MaxPVcharger
current
[
36] 80A
default
Max PV charger current. Setting range: 0~80A