![SPX Waukesha Cherry-Burrell CM Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/spx/waukesha-cherry-burrell-cm/waukesha-cherry-burrell-cm_instruction-manual_1352592008.webp)
95-03028
08/2010
8
GlanD
OIl leVel
OIl DRaIn
bReaTheR caP
7. MeThOD OF FeeDInG anD caPacITY
The inlet and outlet ports are 2 inch sanitary male threads.
The inlet port is located in the body—its position can be
changed. (See variation of inlet port diagram; page 8).
The outlet port is located in the cover of the mill. The mill
must be fed with a pump. A Waukesha Cherry-Burrell
positive displacement type pump is recommended. The
capacity of the mill is 400 to 2000 gallons per hour (6.6
to 33.3 gallons per minute).
InleT
OuTleT
Figure 4
Figure 5
Figure 6
InsTallaTIOn anD sTaRT-uP
6. lubRIcaTIOn
The mill is shipped with oil in the bearing case. The level
should be checked at the oil level hole and if necessary,
oil should be added through the oil fill hole.
use Mobil oil DTE BB ISO Grade 220 R & O (Rust
inhibited) gear oil. (Part No. 00). If DTEBB
is not available use S.A.E. 40 non-detergent mineral
oil. The mill is shipped with a solid cap screw in the oil
fill hole. This should be removed and replaced with the
breather cap which is wired to the mill.
Frequency of lubrication is dependent upon tempera-
ture and moisture conditions. If room temperature is
normal, 70° to 80° F. and water does not contact the
bearing case, change oil every 240 operating hours.
When temperature varies from hot to cold or mill is
flushed out with water, condensation will occur in the
bearing case necessitating more frequent oil changes.
Normal operating temperature of the bear ing case is
170° F. to 190° F.
3. WIRInG
3 Phase, 60 Cycle, 230-460 Volts. Follow wiring direc-
tions on motor. Check direction of rotation.
4. ROTaTIOn
Counter-clockwise when facing outlet port. If run
clockwise the rotor retaining nut may back off resulting
in damage to the mill.
5. seal Flush
The mill is equipped with a face type seal which must
be water cooled. The
In
and
OuT
ports for introducing
the water to the seal are located in the gland (1)
They
are 1/4-inch pipe nipples, but the IN hole is smaller
than the OUT hole to prevent over-pressurizing.
(Figure 4)
The
In
port must be used and the flow of water must
be throttled to produce a
flush of 1/2 to 1 quart per
minute. Flows in this range provide safe cooling
without damage to lip seal.
It is recommended that a solenoid valve be used in
the water line to turn on the water simultaneously
with the mill. If the solenoid valve is not used the
water flush line should be turned on before starting
mill.
Содержание Waukesha Cherry-Burrell CM
Страница 16: ...95 03028 08 2010 16 colloid mill GEAR case Figure 23 PARTS LIST ...
Страница 20: ...95 03028 08 2010 20 NOTES ...
Страница 21: ......