12. Maintenance
Maintenance of the Silentwind generator is not necessary
.
The Silentwind generator is produced for troublefree long-term use.
13. Troubleshooting
In case of problems, however, these can be easily solved.
Windgenerator doesn´t start to run:
Possible Cause
Test
Solution
Not enough wind
Measure the wind speed
(Anemometer)
Wait for more wind, start
up speed is 2,2m/s
Stop switch activated
Switch to run
Enclosed stop switch
wrong installed
Install in line with
instruction
Generator shaft sluggish
Turn manually
Connection windgenerator
charge regulator short
circuit of AC cables, short
circuit of generator,
customer service
Windgenerator doesn´t charge:
Possible cause
Test
Solution
Not enough wind
Measure the wind speed
Start up of charging
depends on the battery
status, check the
adjustment of the charge
regulator
Electric wiring interrupted Check wires, connections
and gadgets
Replace damaged wires or
gadgets
Fuse is gone
Check fuse
Replace fuse ore cool
down the automatic circuit
breaker
Carbon brushes in the yaw
shaft have no contact
Check carbon brushes and
springs
Replace carbon brushes
and reactivate springs