background image

Grounding Instructions

This product must be grounded.  In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current.  This product
is equipped with a cord having a grounding wire with an
appropriate grounding plug.  The plug must be plugged into an
outlet that is installed properly and grounded in accordance
with all local codes and ordinances.

Improper installation of the grounding plug can result in a
risk of electric shock.

If repair or replacement of the cord or plug is necessary, do not
connect the green grounding wire to either flat blade terminal.
The wire with insulation having an outer surface that is green,
with or without yellow stripes, is the grounding wire and must
be connected to grounding pin.
Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood, or if in
doubt as to whether the product is grounded properly. Do not
modify the plug provided; if it will not fit the outlet, have the
proper outlet installed by a qualified electrician.
This product is for use on a nominal 120 volt circuit, and has a
grounding plug that looks like the plug illustrated in sketch A.
A temporary adapter that looks like the adapter illustrated in
sketch B and C may be used to connect this plug to a 2 pole
receptacle as shown in sketch B if a properly grounded outlet
is not available. The temporary adapter should be used only
until a properly grounded outlet (sketch A) can be installed by
a qualified electrician.  The green colored rigid ear lug, or the
like extending from the adapter must be connected to a
permanent ground such as a properly grounded outlet box
cover.  Whenever the adapter is used, it must be held in place
by a metal screw. 

Service

Should your spray system need service during the warranty
period, return your unit and the proof of purchase to the
distributor where it was purchased.  At our option, the unit will
be repaired or replaced.  In a continued commitment to
improve quality, we reserve the right to make component or
design changes when necessary.

(A)

(C)

(B)

WARNING

Introduction

This High Volume/Low Pressure (HVLP) spray system is
designed for applying coatings to surfaces that can be sprayed
faster than brushing or rolling and are too small for traditional
airless sprayers.  Components of this system include a power
switch, a power cord, a replaceable fuse, a dual filtration
system, a cup holder, an air hose, and an air outlet.

With this HVLP spray system, you can achieve the highest
quality professional finish possible with little or no preparation
or setup time.  Please review all the information contained in
this manual before operating the system.

Using an HVLP Spray System

Refer to the following information to operate and understand
your HVLP spray system.

Setup

Use the following procedure to set up your HVLP spray system
for operation.

1. Plug the turbine power cord into a grounded, 3-slot

receptacle.

Keep the turbine at the maximum possible distance from
the spray area to safeguard against explosion or fire that
may be caused by sparking electrical parts.

2. Prepare your spray gun for operation.  Refer to your spray

gun manual for material preparation, setup, and spraying
information.

3. Attach the air hose to the air outlet on the turbine.
4. Attach the air hose to the air inlet on your spray gun.
5. Turn on the turbine and begin spraying.

WARNING

Air Outlet

Cup Holder

Fuse

Filter (in end

of filter can)

Power Cord

Power Switch

Filter

Air Hose

© 1999 SprayTECH Corporation.  All rights reserved.

3

English

Содержание CAPspray CS5100

Страница 1: ...Notice d utilisation Manual del Propietario 0999 1999 SprayTECH Corporation All rights reserved Form No 0277754E CAPSpray 1770 Fernbrook Lane Minneapolis MN 55447 CS5100 Spray System Owner s Manual N...

Страница 2: ...vement of couplings before each use If any of these conditions exist replace the hose immediately Never repair a paint hose Never aim the spray gun at any part of the body HAZARD HAZARDOUS VAPORS Pain...

Страница 3: ...ounded outlet box cover Whenever the adapter is used it must be held in place by a metal screw Service Should your spray system need service during the warranty period return your unit and the proof o...

Страница 4: ...Clean the filters Either tap the filters to knock out the contaminants or use pressurized air to blow out the contaminants For material that is not blown or knocked loose easily soak the filters in so...

Страница 5: ...r supply 2 The fuse is blown 3 Worn turbine brushes 1 Worn turbine brushes 2 Damaged commutator English Troubleshooting Problem Restricted air flow or no air flow The turbine has no power Excessive ar...

Страница 6: ...haque usage Le cas ch ant il faut remplacer le tuyau sur le champ en ne tentant jamais de le r parer On ne doit jamais orienter le pistolet vers une partie du corps DANGER MANATIONS DANGEREUSES Les pe...

Страница 7: ...hez qui on l a achet Il sera alors selon le choix du fabricant r par ou remplac Dans le cadre de son engagement perp tuel envers l am lioration de la qualit nous r servons le droit de modifier les com...

Страница 8: ...petits coups sur les filtres pour vacuer les contaminants ou utiliser de l air comprim pour les chasser Pour les mati res qui ne sont pas vacu es facilement tremper les filtres dans de l eau savonneu...

Страница 9: ...les filtres 1 V rifier l alimentation lectrique 2 V rifier et remplacer le fusible si n cessaire 3 Faire remplacer les balais par un centre de service agr CAPSpray 1 Faire remplacer les balais par un...

Страница 10: ...abolladuras as como uniones da adas o que se hayan movido Si existiera cualquiera de estas condiciones reemplace la manguera inmediatamente Nunca repare una manguera de pintura Nunca apunte la pistola...

Страница 11: ...a tierra de acuerdo con todos lo c digos y normas locales Una instalaci n inapropiada de la clavija de conexi n a tierra puede resultar un riesgo de choque el ctrico Si es necesario reparar o reempla...

Страница 12: ...os no se da an con esta operaci n 2 Limpie los filtros Puede sacudir los filtros para sacar los contaminantes o usar aire comprimido para sopletear los contaminantes Para material pegado dif cil de se...

Страница 13: ...filtros 1 Revise la fuente de poder 2 Revise y cambie el fusible 3 Mande cambiar los cepillos en un centro de servicio autorizado CAPSpra 1 Mande cambiar los cepillos en un centro de servicio autoriza...

Страница 14: ...r r guli rement les filtres Les filtres engorg s peuvent engendrer une surchauffe et peut tre endommager l unit Pour obtenir de plus amples renseignements en mati re de diagnostic des anomalies consul...

Страница 15: ...0277407 Espuma contra ruido de ventilador 2 20 0277393 Cubierta del recipiente 1 21 0277396 Base de montaje del recipiente 6 22 0276598 Disco de espuma 1 23 0277501 Soporte 1 24 9802234 Tornillo 3 25...

Страница 16: ...entre d entretien autoris par CAPspray 2 La pr sente garantie ne couvre pas l quipement et les accessoires fournis CAPspray par un fabricant de mat riel original OEM incluant sans toutefois s y limite...

Страница 17: ......

Отзывы: