This airless sprayer is a precision power tool used for spraying
many types of materials.  Read and follow this Owner’s
Manual carefully for proper operating instructions,
maintenance, and safety information.

Operation

This equipment produces a fluid stream at extremely high

pressure.  Read and understand the warnings in the

Safety Precautions section at the front of this manual

before operating this equipment.

Setup

Perform the following procedure before plugging in the power
cord of an electric sprayer.

1. Ensure that the siphon tube and the return hose are

attached and secure.

2. Using a wrench, attach a minimum of 50’ of 1/4” nylon

airless spray hose to the outlet fitting on the sprayer.
Tighten securely.

3. Attach an airless spray gun to the spray hose.  Using two

wrenches (one on the gun and one on the hose), tighten
securely.

Make sure all airless hoses and spray guns are electrically

grounded and rated at or above the maximum operating

pressure range of the airless sprayer. 

4. Make sure the pressure control knob is turned fully

counterclockwise to its lowest pressure setting.

5. Make sure the ON/OFF switch is in its OFF position.
6. Fill the oil cup with approximately one tablespoon of

separating oil (P/N 0279920).

Never operate unit for more than ten seconds without

fluid.  Operating this unit without fluid will cause

unnecessary wear to the packings.

7. Make sure the electrical service is 120V, 15 amp

minimum.

8. Plug the power cord into a properly grounded outlet at

least 25’ from the spray area.

CAUTION

WARNING

NOTE: Do not attach the tip to the spray gun yet.

Remove the tip if it is already attached.

WARNING

Pressure Control 

Knob

ON/OFF 

Switch

PRIME/SPRAY 

Valve

Outlet Fitting

Circuit 

Breaker

Oil Cup

Siphon 

Tube

Return 

Hose

Filter

4

© SprayTECH.  All rights reserved.

Always use a minimum 12 gauge, three-wire extension

cord with a grounded plug.  Never remove the third prong

or use an adapter.

Preparing a New Sprayer

If this sprayer is new, it is shipped with test fluid in the fluid
section to prevent corrosion during shipment and storage.
This fluid must be cleaned out of the system thoroughly with
mineral spirits before spraying paint.

Always keep the trigger lock on the spray gun in the

locked position while preparing the system.

1. Place the siphon tube into a container of mineral spirits.
2. Place the return hose into a metal waste container.
3. Set the pressure to minimum by turning the pressure

control knob fully counterclockwise.

4. Move the PRIME/SPRAY valve down to

the PRIME position.

5. Turn on the unit by moving the ON/OFF

switch to the ON position.

6. Allow the sprayer to run for 15–30 seconds

to flush the test fluid out through the return
hose and into the waste container.

7. Turn off the unit by moving the ON/OFF switch to the OFF

position.

Preparing to Paint

Before painting, it is important to make sure that the fluid in the
system is compatible with the paint that is going to be used.

Always keep the trigger lock on the spray gun in the

locked position while preparing the system.

1. Place the siphon tube into a container of the appropriate

solvent.  Examples of the appropriate solvent are water for
latex paint or mineral spirits for oil-based paints.

2. Place the return hose into a metal waste container.
3. Set the pressure to minimum by turning the pressure

control knob fully counterclockwise.

4. Move the PRIME/SPRAY valve down to

the PRIME position.

5. Turn on the sprayer by moving the ON/OFF switch to the

ON position.

6. Allow the sprayer to run for 15–30 seconds to flush the old

solvent out through the return hose and into the metal
waste container.

NOTE: Hold the return hose in the waste

container when moving the

PRIME/SPRAY valve to PRIME in

case the sprayer is pressurized.

CAUTION

NOTE: Incompatible fluids and paint may cause the

valves to become stuck closed, which would

require disassembly and cleaning of the

sprayer’s fluid section.

Pressure Control 

Knob

ON/OFF 

Switch

CAUTION

CAUTION

Содержание 0551010

Страница 1: ...the U S A EPX2155 Piston Pump SprayTECH 1770 Fernbrook Lane Minneapolis MN 55447 Technical Assistance 1 800 292 4637 Order Entry 1 800 443 4500 Fax 1 800 525 9501 www spraytechinc com Owner s Manual M...

Страница 2: ...URE RELIEF PRESSURE described in the pump manual ALWAYS keep tip guard in place while spraying The tip guard provides some protection but is mainly a warning device ALWAYS remove the spray tip before...

Страница 3: ...els guns and accessories must be pressure rated at or above the maximum operating pressure range of the airless sprayer Do not spray outdoors on windy days Wear clothing to keep paint off skin and hai...

Страница 4: ...er remove the third prong or use an adapter Preparing a New Sprayer If this sprayer is new it is shipped with test fluid in the fluid section to prevent corrosion during shipment and storage This flui...

Страница 5: ...E SPRAY valve up to the SPRAY position 10 Turn on the sprayer 11 Unlock the gun by turning the gun trigger lock to the unlocked position Ground the gun by holding it against the edge of the metal cont...

Страница 6: ...ON OFF switch to the OFF position and unplug the sprayer Practice 1 Be sure that the paint hose is free of kinks and clear of objects with sharp cutting edges 2 Turn the pressure control knob counterc...

Страница 7: ...ose in the waste container when moving the PRIME SPRAY valve to PRIME in case the sprayer is pressurized WARNING SprayTECH All rights reserved 7 Do not attempt to clean the tip with your finger Do not...

Страница 8: ...bly away from the gear box housing 4 Disconnect the five wires from the relay that is mounted on the inside of the heat sink assembly 5 Remove the three relay mounting screws from the heat sink assemb...

Страница 9: ...Screw Crankshaft Gear Assembly Armature Gear Motor Motor Cover Motor Cover Screw NOTE Refill the gear box with five ounces of Lubriplate P N 9870307 NOTE If the motor will not dislodge from the pump...

Страница 10: ...n rod attached to the pump This will prevent the piston rod from rotating during disassembly of the outlet valve Outlet Valve Retainer Outlet Valve Seat Outlet Valve Ball Outlet Valve Cage Piston Rod...

Страница 11: ...hose clip on the siphon tube 19 For Low Boy cart units insert the elbow on the suction set assembly into the bottom of the inlet valve housing Push the retaining ring up into the groove inside the in...

Страница 12: ...ats following the Servicing the Fluid Section procedure in the Maintenance section of this manual 10 Take unit to a SprayTECH authorized service center 1 Repack the pump following the Servicing the Fl...

Страница 13: ...hose with a minimum of 50 of 1 4 grounded textile braid airless paint spray hose 2 Replace the spray tip following the instructions that came with the spray gun 3 Rotate the pressure control knob cou...

Страница 14: ...tion particuli re ATTENTION AVERTISSEMENT DANGER RISQUES D EXPLOSION OU D INCENDIE Les vapeurs d gag es par le solvant ou la peinture sont explosives et inflammables et peuvent causer des corporels s...

Страница 15: ...ur assume tous les risques et responsabilit s lorsqu il utilise des pi ces qui ne sont pas conformes aux caract ristiques techniques minimales ainsi qu aux dispositifs de s curit du fabricant de la po...

Страница 16: ...PARA PREVENIR Debe proveerse un escape y aire fresco para hacer que el aire que est dentro del rea de atomizaci n se mantenga libre de acumulaciones de vapores inflamables Evite todas las fuentes de i...

Страница 17: ...cela con otra manguera conectada a tierra Todas las mangueras soportes giratorios pistolas y accesorios que se usen con esta unidad deben tener una capacidad de presi n de 3000 lb pulg2 20 7 MPa o may...

Страница 18: ...y 2 9 0507783 Hose clip upright cart only 1 10 0508552 Siphon tube upright cart only 1 11 0551556 Return hose upright cart only 1 12 5006536 Inlet screen upright cart only 1 Item Part Description Quan...

Страница 19: ...or Brush Kit NOTE All electrical work should be performed by a SprayTECH authorized service center Motor Assembly Suction Set Assembly P N 0551104 Item Part Description Quantity 1 0551437 Siphon tube...

Страница 20: ...yTECH All rights reserved 1 2 3 4 5 9 10 11 12 13 14 15 16 17 18 6 7 8 19 18 20 21 22 23 25 24 26 27 28 NOTE All electrical work should be performed by a SprayTECH authorized service center Gear Box A...

Страница 21: ...9 9850936 ON OFF switch 1 20 03662 Microswitch insulator 1 21 0295490 Microswitch 1 22 9800604 Screw 2 23 0295451 Relay 120V 1 24 0507751 Port plug 1 25 0509218 Screw 4 26 0551523 Heat sink assembly i...

Страница 22: ...assembly 1 8 0551539 Lower packing assembly 2 9 0551537 Piston rod 1 10 0295307 Outlet valve cage 1 11 50164 Outlet valve ball 1 12 13359 Outlet valve seat 1 13 13481 Outlet valve retainer 1 14 050867...

Страница 23: ...cription Quantity 1 0551608 Cart weldment includes items 6 and 14 1 2 0507956 Roll pin 2 3 0294534 Wheel spacer 4 4 0270394 Wheel 2 5 9890104 Cap 2 6 0551548 Plug 2 7 0295615 Lock nut 2 8 0507955 Scre...

Страница 24: ...TECH HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW THE DURATION OF ANY IMPLI...