12.16 LEVEL SENSOR INPUT
A level switch (any normally open or normally closed float switch) can be wired to the system, so when the tank level
drops below a certain level, a fault will be shown on the HMI.
Wire the level sensor/float switch to the panel utilizing the cable shown below. You will only use the black and blue
wires (dry contacts
-
polarity not important), carefully cut back and tape the brown and white wires. Run the cable
back to the spray control panel and plug into the port labeled
“
T. Int.
”.
Activate level sensor option, go to settings in the HMI then
“
Tank level
”
and turn on.
Specifications:
•
Part number: LE00M8F5M.
•
Panel connection: T. int. (Software
-
DI2+DI4)
•
Cable: 16.4 ft. (5 m) cord length
•
Flying leads
•
Connector end
-
M8 4 pin female
•
Cable, M8 Female, 4 pole, bare leads, 5 meter