5.2 FLUID RESERVOIR CONNECTIONS
FLUID LINES
The fluid line originates from the fluid reservoir and connects to the pump. The line then runs out to the electrostatic
nozzle through 1/4 in. OD push
-
to
-
connect fittings.
AIR LINES
The air input connects to the air pressure regulator using 1/4 in. NPT. The regulator connects to the pump through
1/4 in. OD push
-
to
-
connect (Tube) fittings.
Figure 5.2
-
1: Pump connection diagram
Figure 5.2
-
2: Air connections diagram
Pump Connections Side View
Air Connections Side View
Air Pressure Regulator
(Connect to Block J9 Input 9)
Pump Adjustment
Knob
Pump Air Inlet (A)
Pump Fluid Inlet
Pump Fluid Outlets
(To Nozzle)
Reservoir Tank Fluid
Outlets (To Pump)
Air Pressure
Adjustment Knob
Air Out (A) to Pump
1/4”
OD Tube
Fluid Level Float Switch
(Connect to Block J9 Input 10)
Air In
1/4”
NP
Pump Solenoid Cable (Connect
to Block J10 Output 10)
Pump Air Inlet (B)
Air Out (B) to Pump
1/4”
OD Tube