INPUT DESCRIPTIONS: J9 TERMINAL BLOCK
Not all inputs need to be used. The user should determine which inputs are most important for the application.
Odd numbered connections are for +24 VDC power source; even numbered connections are for connection to positive
side of the load.
INPUT
TERMINAL
CONNECTION
DESCRIPTION
1
1 & 2
Momentary Closure = PRIME MODE
A momentary closure in this circuit activates PRIME MODE. (ref. prime
mode description in System Modes section)
2
3 & 4
Momentary Closure = TEST MODE
A momentary closure in this circuit activates TEST MODE. (ref. test mode
descriptionin System Modes section)
3
5 & 6
Maintained Closure = RUN MODE
A momentary closure in this circuit activates RUN MODE. (ref. run mode
description System Modes section)
4
7 & 8
Maintained Closure = BURST MODE
A momentary closure in this circuit activates BURST MODE. (ref. burst
mode description System Modes section)
5
9 & 10
Open Switch = FAULT 1
For use with pressure sensors. System will fault when pressure is below
range.
6
11 & 12
Open Switch = FAULT 2
For use with pressure sensors. System will fault when pressure is above
range.
7
13 & 14
Open Switch = FAULT 3
For use with pressure sensors. System will fault when pressure is below
range.
8
15 & 16
Open Switch = FAULT 4
For use with pressure sensors. System will fault when pressure is above
range.
9
17 & 18
Open Switch = AIR PRESSURE FAULT
Air pressure guage/sensor to be wired here. System faults if air pressure
falls below set limit on the guage/sensor.
10
19 & 20
Open Switch = OIL LEVEL
Level switch wired here. System will fault when level switch is active.
Note: Wire colors and terminals.