TSL.R.030 RIBBON HAND DRYER MANUAL     19

Corrective Actions for Initial Installation Failures 

If the dryer will not run:

 

+

First ensure that the breaker supplying the dryer is operational. If it is, disconnect 
the power and remove the dryer cover. Replace the CBM and IR sensor module. 
Taking suitable precautions to avoid shock hazard, reconnect the power and 
check for Voltage at the terminal block.

The IR sensor only sees close range objects:

 

+

Ensure that there is no obstruction on or in front of the IR sensor. Clean any dirt 
or debris off the sensor lens. Check variable resistor for sensor range setting, If 
problem persists, disconnect the power and remove the dryer cover and replace 
CBM, IR sensor module.

The heater gets hot but no air stream is produced:

 

+

Disconnect the power. Remove the dryer cover. Check variable resistor for speed 
setting Disassemble the blower- motor/ fan housing. Replace the fan motor. 
Reassemble.

Содержание TSL.R.030 Series

Страница 1: ...TSL R 030 ribbon hand dryer installation maintenance...

Страница 2: ...cal Data 6 Before You Install 8 How to Install 14 Commissioning 16 Operation 16 Maintenance 17 Cleaning 18 Troubleshooting 21 Diagram 22 Spare Parts Accessories 23 Warranty Back Cover Contact Details...

Страница 3: ...iring in accordance with the current local regulations in force Disconnect the power supply before performing any maintenance on the product Children should not play with this equipment Cleaning and m...

Страница 4: ...NUAL box contents A B C D E F G K H J A Dryer head assembly B Hand dryer motor unit C Power cable D Anti rotation collar already installed E Gasket F Anti rotation washer G Fixing nut H Motor mounting...

Страница 5: ...z Material AISI 304 stainless steel Noise levels 70 6dB Heating element 500W Motor type Brush type dual ball bearings Motor power 500 350W Air speed 367 ft s Air flow 25 3 cu ft min Sensor range 5 1 S...

Страница 6: ...native basin is used then appropriate mounting points must be created in basin or countertop to accommodate the Ribbon products Power supply A 15A fused supply must be provided for connection to the m...

Страница 7: ...ND DRYER MANUAL 7 before you install 2 1 8 6 7 5 16 4 3 8 5 5 8 3 8 MIN 1 3 8 MAX Default Sensor Range 3 4 5 1 8 Mains Power Supply 5 7 8 12 1 16 10 3 4 11 3 4 12 9 16 7 9 16 1 5 16 THROUGH HOLE 2 11...

Страница 8: ...8 TSL R 030 RIBBON HAND DRYER MANUAL how to install 1 Drill hole 1 3 8 diameter in counter top if not already cut 2 Fit anti rotation washer from below basin...

Страница 9: ...TSL R 030 RIBBON HAND DRYER MANUAL 9 3 Fit fixing nut and secure using spanner 4 Remove cover fixing screws from underside of dryer motor using the security hex key provided and then remove the cover...

Страница 10: ...dryer motor unit to wall or cabinet within 18 of the dryer nozzle already installed on the basin countertop 6 Thread the power cable through the knockout in the back or base of the dryer and feed to...

Страница 11: ...TSL R 030 RIBBON HAND DRYER MANUAL 11 7 Thread the sensor and earth cables through the air hose 8 Feed cables into air outlet nozzle and then through cable exit grommet...

Страница 12: ...ow to install 9 Connect the sensor cable to the 6 pin fitting on the PCB control and the ground cable to the corresponding earth connector in the dryer motor unit 10 Connect air hose onto outlet nozzl...

Страница 13: ...TSL R 030 RIBBON HAND DRYER MANUAL 13 11 Re fit the dryer cover and tighten the fixing screws...

Страница 14: ...be switched off if desired Warm air speed adjustment 1 Switch off the power loosen the cover screws and remove the cover 2 Use small Phillips head screwdriver to turn variable resistor shaft Turn clo...

Страница 15: ...t Switch ON OFF 1 Switch off the power loosen the cover screws and remove the cover 2 Adjust the heater switch on the PCB with a small plastic or wood flat blade probe 2 1 Slide the switch to ON Enabl...

Страница 16: ...op when the user s hands are removed from the detection range maintenance The hand dryer should be serviced on a regular basis to ensue long service life of the unit Isolate the unit from the power su...

Страница 17: ...ular washroom janitorial routine Do not use abrasive or cream cleaners as these will damage the surface finish If the hand dryer is subjected to a highly chlorinated environment eg swimming pools or m...

Страница 18: ...ace sensor The dryer makes a loud noise and does not run for a complete cycle Ensure that the supply voltage is correct Dryer will make a loud humming noise if the input voltage is too high Verify vol...

Страница 19: ...ck for Voltage at the terminal block The IR sensor only sees close range objects Ensure that there is no obstruction on or in front of the IR sensor Clean any dirt or debris off the sensor lens Check...

Страница 20: ...e heater element for signs of burning or breakage Damaged element must be replaced The air stream is low pressure and velocity Check the output nozzle for obstructions If none are present disconnect t...

Страница 21: ...TSL R 030 RIBBON HAND DRYER MANUAL 21 diagram 1 2 3 6 7 9 8 26 25 24 23 22 21 20 19 38 18 17 16 15 14 13 12 11 11 4 5 29 28 27 30 31 32 33 34...

Страница 22: ...rubber Upper 16 Blower motor housing upper section 17 Stainless steel front cover plate 18 Motor cover fixing screws 2 required 19 Hex wrench 20 Motor case cable entry grommet 21 Terminal block 22 Ma...

Страница 23: ...ars parts labour If a defect is found in normal use The Splash Lab will at their discretion repair provide a replacement part or product or make appropriate adjustments Damage caused by accident misus...

Страница 24: ...ormation 1 310 410 5008 5450 W 83rd St Los Angeles CA90045 500 7th Ave New York NY10018 Technical support technical thesplashlab com For further contact information visit www thesplashlab com TSL R 03...

Отзывы: