background image

 

 2 

 

 

Spitwater  Australia  is  proudly  Australian  owned  and  operated  since  1983.  Our  promise  is  to  provide  our 
customers with superior quality high pressure cleaners built to the highest of standards that will see many years 
of reliable service. 
The Spitwater range of high pressure cleaners has been designed to give safe, efficient and dependable service 
when  the  correct  operating  and  safety  instructions  are  followed  and  proper  attention  is  given  to  all  required 
maintenance procedures in order to maintain the unit in peak operating condition. 
This manual provides the up to date information necessary for the user to operate the unit and carry out regular 
inspection and maintenance. 
Please note that the information given within this manual may be subject to revision in compliance with Spiwater 
Australia’s policy of continual improvement. 
Spitwater high pressure cleaners should only be used in the manner and purpose for which they

 

were intended 

and in accordance with the recommendations and safety precautions detailed in this manual.  
All Spitwater high pressure cleaners undergo rigorous safety and operational tests before being dispatched into 
the market, however it is still imperative that prior to use, all operators have read and understood all information 
and instructions provided and are aware of possible hazards. 

 
 
 

Spitwater high pressure cleaners are specifically designed to solve all problems relating to washing, degreasing, 
descaling  and  disinfecting  in  a  wide  range  of  commercial  and  industrial  situations.  Some  examples  of 
applications are in the cleaning, building, transport, light and heavy manufacturing and primary industries. 

 
 
 

Spitwater has an extensive range of spare parts and accessories to suit all your cleaning needs. For spare parts, 
accessories and service please contact 

1800 SPITWATER (1800 774 892)

 and to view Spitwater's extensive 

range of high pressure cleaners online visit 

www.spitwater.com.au 

For international spare parts, accessories and service please contact 

[email protected]

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INTRODUCTION 

GENERAL DESCRIPTION & INTENDED USE 

SPARE PARTS, ACCESSORIES AND AFTER SALES SERVICE 

Содержание SHW85

Страница 1: ...rstand this instruction manual before operating this unit and retain for future reference Failure to follow operating safety and maintenance instructions outlined in this manual releases the manufactu...

Страница 2: ...ccordance with the recommendations and safety precautions detailed in this manual All Spitwater high pressure cleaners undergo rigorous safety and operational tests before being dispatched into the ma...

Страница 3: ...LECTRIC POWER 15 15 HP PUMP MODEL T2535 T2535 OIL TYPE 15W 40 15W 40 OIL CAPACITY 1 2 1 2 L OTHER BURNER PRESSURE 10 10 BAR VALUES DETERMINED AS PER AS NZS 60335 2 79 SOUND PRESSURE LEVEL Lp 87 87 dB...

Страница 4: ...meaning is listed next to them for your attention CAUTION Hot surface Do not touch DESCRIPTION OF SYMBOLS IMPORTANT SAFETY INSTRUCTIONS AND PRECAUTIONS WARNING This high pressure cleaner shall only be...

Страница 5: ...h label Do not alter or remove safety labels WATER INLET CONNECTOR SERIAL LABEL TRIGGER HIGH PRESSURE HOSE MOUNTING HOLES HIGH PRESSURE ON OFF HIGH PRESSURE WATER OUTLET CONNECTOR DIESEL INLET BURNER...

Страница 6: ...do so DO NOT operate the unit without appropriate personal protective equipment PPE 2 ELECTRICAL CONNECTION The voltage hertz rating and number of phases on the serial label must correspond to that o...

Страница 7: ...they cross pathways Take safety measures like placing traffic cones along the cord or tape the cord to the floor with duct tape 6 FIRE PREVENTION AND HOT SURFACE CAUTION Store flammable fluids in app...

Страница 8: ...fuel and or lubricants are spilled clean immediately DO NOT mix petrol or alcohol with diesel fuel Incorrect fuels shall not be used as they may prove hazardous Use only clean and approved fuel store...

Страница 9: ...user is subject to very strong recoil forces and torque There is a risk of high pressure water jet injury Never aim the jet at yourself other people or animals as this could result in serious injuries...

Страница 10: ...could damage the unit Keep flammable materials away from and do not place anything on the unit while it is running Pressure regulating valve This unit is equipped with a pressure regulating valve whic...

Страница 11: ...in order to prevent it from sliding or falling 4 If transporting the unit make sure there is no possibility for the temperature to be at or below 0 C If it is necessary to transport the unit at or be...

Страница 12: ...t incorrect voltage or insufficient power supply will cause immediate damage to the unit Note Any work needed on initial installation to connect the unit to the power supply must be carried out by a q...

Страница 13: ...do not interchange during assembly Add nozzle shield after nozzle assembly Refer diagram below 10 LANCE TRIGGER GUN HIGH PRESSURE HOSE ASSEMBLY Connect the lance to the spray gun by an in built quick...

Страница 14: ...service agent if found Open the water supply and fill the water tank The float valve will automatically stop the water flow when the water tank is full Water that has flowed through backflow prevente...

Страница 15: ...15 13 Remove the DIESEL tank cap and fill the diesel tank with clean filtered diesel ONLY USE CLEAN DIESEL IN THIS UNIT as using any other fuel will create a risk of explosion and damage to the unit...

Страница 16: ...few minutes to expel air from the hydraulic system If air remains in the system open and close the spray gun a few times to expel Note If this is the first use of the unit or the unit has been left id...

Страница 17: ...ment knob to achieve desire cleaning temperature USAGE TIPS Use the unit as necessary to carry out cleaning while trying to minimize where possible opening and closing the spray gun trigger as this wi...

Страница 18: ...for cleaning TO STOP 1 Make sure burner switch is in OFF position 2 Press the OFF power button 0 of the unit 3 Release all trapped water pressure in the unit by pulling the trigger of the spray gun th...

Страница 19: ...s that have been set and sealed at the factory Never under any circumstances tamper with modify or adjust these settings 7 Make sure this unit is regularly serviced by an authorized Spitwater service...

Страница 20: ...rvice due based on USAGE VS SERVICE FREQUENCY Table A Proper function of burner switch temperature controller emergency stop and pressure gauge Check for water leaks at high pressure hose fittings Che...

Страница 21: ...y Time interval for checks and replacement listed above are for units subjected to normal operating conditions Should the unit be subjected to abnormal conditions e g heavy use dirty water extreme tem...

Страница 22: ...ve the fastening knob and the oil level cap Check the oil level in the pump using the dipstick or the sight glass on the back side of the pump Make sure the level is between min max level notches on t...

Страница 23: ...off is activated Check that water diesel tank are full and add water diesel as necessary No power supply Contact an authorized electrician to check power supply When switch is activated the motor hum...

Отзывы: