1.
Inspect the unit every day to confirm that it is safe
and in proper working order before putting it into
service. Follow the
“DAILY INSPECTION
CHECK LIST”
in the SERVICE / CARE section
as a guide. If the unit is damaged or faulty in
anyways, DO NOT use it and immediately contact
your authorized Spitwater service agent for
advice.
TO START
1. Always wear appropriate Personal Protective
Equipment. (PPE)
2. Press the ON power button (I).
TO USE
1. Release the spray gun trigger lock.
2.
Pull the trigger on the spray gun and allow water
to run through the system for a few minutes to
expel air from the hydraulic system. If air
remains in the system, open and close the spray
gun a few times to expel.
Note: If this is the
first use of the unit or the unit has been left
idle for an extended period of time it is
advisable to run this operation with the front
part of the lance disconnected in order to
avoid debris or scale being lodged in the
nozzle and blocking it.
3. Check that the pressure indicated on the pressure
gauge matches the value on the data plate and in
the technical data. Also check that when the trigger
is released the pressure shown on the gauge
returns to zero.
GENERAL PRE-START CHECK
OPERATING INSTRUCTIONS
5
Seconds Rule:
DO NOT pull the trigger for the
first five seconds once pressing the ON power
button (I).