Operator’s Manual – Spider CROSS LINER
52 / 62
BATTERY TESTING
The best and easiest way to test the battery is to use a voltmeter or a multimeter to measure the resting voltage. If
you know the exact voltage, use the table below to determine the charge.
Make sure that the battery is fully charged so it can provide enough starting energy. The recommended charging
current is 10% of the nominal capacity in amperes, i.e. 1.0A [ampere]). To ensure long life, we recommend that the
battery be fully charged before installation.
8.12 NEUTRAL POSITION ADJUSTMENT
During the use of the mower, the neutral position of the servomotor may be off-center, and the mower will start to
drive automatically. In this case, it is necessary to adjust the neutral position.
PROCEDURE:
1) Place the mower on a flat firm surface.
2) Raise the mower to the
so that the machine mowing deck touches the ground
and the wheels are clear off the ground.
3) Start the engine.
4) Loosen the lock nuts (13mm wrench) on the traction actuator linkage.
5) Adjust the tightening of the joints so that the wheels do not move forward or backward once in the neutral
position.
6) Tighten the lock nuts.
Resting voltage
Charge status
Action required
More than 12,6 V
100 %
No action is required
12,40
– 12,54 V
70 %
No action is required
12,24
– 12,40 V
50 %
Charge the battery
11,88
– 12,18 V
20 %
Charge the battery immediately
Less than 11,8 V
0 %
Battery must be replaced
ACTUATOR TRAVEL
ROD
LOCKING NUT
Содержание CROSS LINER