- First, open any one of the outlet valves at the outlet
of the water heater. Next, open the inlet valve. The
water heater gets filled with water. When water flows
out of the outlet pipe it implies that the heater has
been fully filled with water and the outlet valve can
be closed.
Note: During normal operation, the inlet valve must
always be kept open.
- Insert the supply plug into the supply socket and
Switch ON
. The power indicator and the heating
indicator will light up.
- The thermostat will automatically control the
temperature. When the water temperature inside the
heater has reached the set temperature, it will
Switch
OFF
automatically. When the water temperature falls
below the set point the heater will be turned on
automatically to restore the heating. When the heater is
switched off automatically, the heating indicator also
Switches OFF.
METHODS OF USE
CAUTIONS
- The supply socket must be earthed reliably. The
rated current of the socket shall not be lower than
16A. The socket and plug must be kept dry to prevent
electrical leakage.
- The installation height of the supply socket must not
be lower than 2m.
- The wall on which the electrical water heater is
installed should be able to bear a load of more than
two times the heater – when fully filled with water.
Other strengthening measures must be adopted in
case of distortion and cracks.
- The multifunction valve attached to the heater must
be installed at the cold water inlet. This valve
performs the function of pressure release, vacuum
release, non-return and drainage.
- When using the heater for the first time (or during
first use after maintenance) the heater must not be
Switched ON
until it has been filled with water. When
filling the water, at least one of the outlet valves at the
outlet of the heater must be opened to exhaust the
air. This valve can be closed after the heater has been
fully filled with water.
- This appliance is not intended for use by persons
with reduced physical, sensory or mental capabilities
or lack of experience and knowledge (including
children), unless they have been given training or
instructions concerning use of the appliance. All
persons are responsible for their own safety.
- The dimension of the multifunction valve and the
inlet/outlet pipe is 1/2” BSP.
- Ensure inlet water pressure is between 0.1 bar to
4 bar (maximum). In case of high water pressure, use
an appropriate Pressure Reducing Valve. Minimum
inlet pressure of 0.1 bar (1m water head) is required
for water to enter the tank.
Thread screw
Drain handle
Pressure release hole
Multi function safety valve
Cold water
Hot water
Fig.04
Fig.05