- The Dimension of Multifunction valve & The Inlet/Outlet
Pipe is 1/2” BSP
- Connection of Multifunction Valve: Install the
Multifunction Valve with The heater on The Inlet of The
Water Heater
- Ensure Inlet Water Pressure between 0.1 Bar to 8 Bar
(Maximum). Incase of High Water Pressure, Use an
Appropriate Pressure Reducing Valve. Minimum Inlet
Pressure of 0.1 bar (1m Water Head) is required for
Water to Enter the Tank.
- If the Users want to realize a Multi- Way Supply System
refer to the method shown in
Fig.3
Connection of the
Pipelines.
- First, Open any one of the Outlet Valves at the Outlet
of The Water Heater, Open the Inlet Valve. The Water
Heater gets filled with Water. When water flows out of
the Outlet pipe it Implies that the Heater has been filled
fully with Water, and the Outlet valve can be closed.
Note: During normal Operation, the Inlet valve shall be
always kept open.
- Insert the supply plug into the supply socket, and
CONNECTION OF PIPELINES
MULTI OUTLET CONNECTION
Connection of Pipelines
Connection of Pipelines