- During heating, there may be drops of water dripping
from the pressure release hole of the multifunction
valve. This is a normal occurrence. If there is a large
amount of water leaking, please contact Spherehot
customer care center for repair. This pressure release
hole shall, under no circumstances, be blocked;
otherwise the heater may be damaging, even resulting
in accidents.
- The drainage pipe connected to the pressure release
hole must always be kept sloping downwards.
- Since the water temperature inside the heater can
reach up to 70°C-80°C, the hot water must not be
exposed to the human body when it is initially used.
Adjust the water temperature to a suitable
temperature to avoid scalding.
- Unscrew the thread screw on the multifunction
safety valve, and lift the drain handle upwards to drain
water from the inner tank.
- Manually operate the safety valve on a regular basis
by lifting the drain handle to remove lime deposits, if
any, and to verify that it is not blocked.
- If the flexible supply cord is damaged, it should be
replaced by professional maintenance personnel with
a new supply cord available with the manufacturer.
- If any parts and components of this electrical water
heater are damaged, please contact Spherehot
customer care center for repair.
MAINTENANCE
- Check the power supply plug and socket frequently
to make sure that they have good, reliable contact
and are well grounded without overheating.
- If the heater is not used for a long time, especially in
regions with low atmospheric temperature (lower
than 0°C), the water inside the heater must be
drained away. This will prevent damage to the heater
due to frozen water in the inner container.
- In order to ensure that the water heater operates
efficiently for a long time, it is recommended that you
clean the inner container and the deposits on the
Note:
Parts illustrated in this use and care manual
are indicative only, parts of the product may differ
from the illustrations. This product is intended for
household use only. Specifications are subject to
change without notice.
electrical heating components periodically.
- It is mandatory to examine the magnesium anode
protection material every six months or earlier to
enhance the life of the inner tank and heating element.
If the magnesium anode is fully consumed, the same
must be replaced on a chargeable basis
WIRING DIAGRAM
Thermal cut-out
Fig.06
Thermostat
230 V/50 Hz AC
Red
Black
Green
Power indicator
Heating indicator
Heating element