SURVIVAIR Opti-Fit

 Convertible Facepiece

21

er’s  instructions  on  the  use  and  maintenance  of 

the respirator. Read and understand the following 

warnings prior to using the respirator.

If  you  are  using  an  ambient  air  pump,  turn  off  the 

pump when the respirator is not in use. Operating the 

pump without a connected supply hose and respira-

tor will cause the pump to overheat. Turn the pump 

on before reentering the work area and verify that the 

pump outlet pressure is correct (See Tables I and II), 

and that the respirator is providing air as described in 

Section VIII, Part B.8.

WARNING

● The respirator consists of a full face

-

piece constructed of silicone with a 

polycarbonate  lens,  EPDM  or  EVA 

breathing  tube,  and  PVC  or  rubber 

air line hoses. It is the user’s respon-

sibility to verify the respirator materi-

als are acceptable for their intended 

use. If you are unsure, consult your 

local  safety  professional  to  verify 

that  no  possible  contaminants  and/

or liquids will permeate through any 

of the respirator materials.

● Do not don, doff, or store the respi

-

rator in an area where contaminants 

can  contact  or  accumulate  inside 

any  component  of  the  respirator. 

Contaminants  inside  the  facepiece, 

breathing tube, or air line hoses may 

be  inhaled  or  absorbed  upon  reuse 

of the respirator.

● Never remove the respirator for any 

reason while in the work area.

● You must leave the work area imme

-

diately if the facepiece-to-face seal is 

disturbed for any reason such as:

Slippage  due  to  sweating  or  ex-

1. 

cessive head movement.

The facepiece becomes dislodged 

2. 

as a result of being knocked.

Sneezing or coughing while wear

-

3. 

ing the facepiece.

You  need  to  blow  your  nose, 

4. 

scratch  your  face,  or  adjust  your 

spectacles.

For  any  other  reason  that  would 

5. 

cause the facepiece seal to be dis-

turbed.

● You  must  restore  the  facepiece-to-

face seal and perform a fit check in 

a non-hazardous environment before 

re-entering the work area.

● FAILURE  TO  COMPLY  WITH  THIS 

WARNING MAY LEAD TO PERSONAL 

INJURY, ILLNESS, OR DEATH.

7. Doffing Instructions for CF-SAR Configurations

a.  Loosen  the  two  lower  head  straps  completely 

(for five strap head harness or Headnet).

b. Grasp the nozzle firmly, and pull the facepiece 

upward over the head.

S – Special or Critical User’s Instructions

8. Pressure Tables for Supplied Air Respirators (SAR)

Table I in Section VIII, Part B.8 provides the pres-

sure range settings for the air supply regulator for 

the  SURVIVAIR  Opti-Fit  Continuous  Flow  Sup-

plied Air Respirator. Refer to Table II when using 

the  vortex  air  cooler.  Refer  to  Section  VI,  Parts 

List, for a listing of the approved air line hose types 

and coupler kits. No more that three (3) lengths of 

9308 Series hose or two (2) lengths of 9852 Series 

hose at the listed pressures may be used. Do not 

mix hose types from different columns.

WARNING

●  Compressors,  storage  cylinders, 

valves, regulators, fittings, and oth-

er hardware must be large enough 

to deliver the air volume required by 

all users at peak demand.

●  You  are  responsible  for  providing 

CGA G-7.1, Type 1, Grade D or bet-

ter air and ensuring compliance with 

safety  and  health  codes  applicable 

to your area.

●  FAILURE  TO  COMPLY  WITH  THIS 

WARNING MAY LEAD TO PERSON-

AL INJURY, ILLNESS, OR DEATH.

CAUTION

Do  not  exceed  the  maximum  continuous 

duty or maximum intermittent duty operat-

ing pressure of the low pressure ambient air 

pump. Refer to your pump user manual.

NOTE

 The third column in Table I should be used 

when  using  a  low  pressure  ambient  air 

pump.  No  more  than  two  (2)  lengths  of 

9852 Series air line hose may be used. The 

air  supply  line  must  be  coupled  to  the  air 

source and the breathing tube with OBAC 

couplers and plugs.

 The vortex air cooler is not approved for use 

with the low pressure ambient air pump.

Содержание SURVIVAIR Opti-Fit 7540

Страница 1: ...PAPR Configurations WARNING DO NOT USE your respirator until you read and completely understand this instruction manual You are required to inspect the adapter prior to putting it into service Please...

Страница 2: ...pm for tight fitting facepieces or six cfm 170 lpm for hoods and or helmet G If airflow is cut off switch to filter and or cartridge and immediately exit to clean air H Follow established cartridge an...

Страница 3: ...How to Use the Respirator 13 5 Doffing Instructions for APR Configuration 13 6 Chemical and Particulate Filter Service Life and Replacement 13 B Continuous Flow Supplied Air Respirator CF SAR Configur...

Страница 4: ...air purifying blower This range of connections allows the SURVIVAIR Opti Fit Convertible facepiece to be configured through the use of additional compo nents as a supplied air respirator CF SAR or pow...

Страница 5: ...following general warnings must be observed for proper operation of all air purifying APR continuous flow supplied air CF SAR and powered air purifying PAPR respirator configurations Additional warni...

Страница 6: ...Limits REL Many chemi cals e g isocyanates Mercury etc have no physical warning properties and you cannot taste or smell the contaminants even though they may WARNING Continued Do not use this respir...

Страница 7: ...e individuals Discontinue use if you experience an allergic reaction Discontinue use if you experience skin irritation or discoloration This product may provide less than adequate protection if improp...

Страница 8: ...rt numbers Air Purifying Respirator APR SURVIVAIR Opti Fit Facepiece Side mount Tube CF Supplied Air Respirator CF SAR SURVIVAIR Opti Fit Facepiece Front mount Tube CF SAR 5 Pt Strap S M L 981500 9815...

Страница 9: ...ible Facepiece Powered Air Purifying Respirator Mask mounted Blower Powered Air Purifying Respirator Belt mounted Blower PAPR CF SAR APR SURVIVAIR Opti Fit Convertible Facepiece Models 5 Pt Headstrap...

Страница 10: ...SURVIVAIR Opti Fit Convertible Facepiece 7 B Parts List Matrix SURVIVAIR...

Страница 11: ...ick coupler kit style Hansen 930840 Quick coupler kit style OBAC Table 3 Powered Air Purifying Respirator PAPR Belt Mounted Cartridges Part No Item Description 150100 OV Cartridge 150200 AG Cartridge...

Страница 12: ...r locking tab from inside the lens and turning the adapter counterclockwise Figures 2 and 3 Insert the nozzle gasket item 25 P N 763016 into the nozzle port Figure 4 Thread in the nozzle plug item 26...

Страница 13: ...tube and therefore the low profile nozzle plug kit cannot be used C Powered Air Purifying Respirator PAPR Both the mask mounted and belt mounted powered air purifying respirator PAPR configurations r...

Страница 14: ...ING Continued for more than 8 hours or one shift even though the calculated service life estimate is greater that 8 hours or one shift These contaminants can mi grate through the canister even when th...

Страница 15: ...3 Verify that two filters and or cartridges are at tached to the threaded side connectors of the facepiece 4 Adjust the top straps until one inch of strap ex tends through each buckle Fully loosen the...

Страница 16: ...adjust the facepiece and head strap then retest If filter retain ers are used do not remove them after the fit check is completed Removing the filter retainers may shift the facepiece and break the fa...

Страница 17: ...e depends on the user s breathing rate the characteristics of the contami nant and the environmental conditions such as temperature and humidity Saturated cartridges will leak trace amounts of contami...

Страница 18: ...ry protection program per OSHA 29 CFR 1910 134 in place then these filters may be used continually but only for a maxi mum of 30 days or 40 total hours whichever comes first Even when used in non oil...

Страница 19: ...s storage cylinders valves regulators fittings and oth er hardware must be large enough to deliver the air volume required by all users at peak demand You are responsible for air quality and complianc...

Страница 20: ...ouplers and plugs FAILURE TO COMPLY WITH THIS WARNING MAY LEAD TO PERSONAL INJURY ILLNESS OR DEATH CAUTION Do not exceed the maximum continuous duty or maximum intermittent duty operat ing pressure of...

Страница 21: ...ns An audible click should be heard when attaching the breathing tube to the front adapter port on the facepiece nozzle See Figure 13 Figure 13 Front Adapter Port and Screw Caps 6 Connect the air line...

Страница 22: ...center the facepiece on your face See Figure 14 6 Hold the facepiece against your face and pull the straps over your head 7 Tighten the two lower straps temple straps then the top straps until a good...

Страница 23: ...escape CF SAR configurations Cover the inlets of the filters with the palms of your hands or another suitable item such as a thin sheet of plastic or rubber NOTE Alternatively the P100 filters may be...

Страница 24: ...seal to be dis turbed You must restore the facepiece to face seal and perform a fit check in a non hazardous environment before re entering the work area FAILURE TO COMPLY WITH THIS WARNING MAY LEAD T...

Страница 25: ...100 you must use another type of respirator The service life of the filter depends on the charac teristics of the contaminant the user s breathing rate and the environmental conditions such as humidi...

Страница 26: ...be charged at temperatures between 40 F and 80 F 4 5 C and 26 7 C Charg ing at higher temperatures may cause a re duction in capacity and may reduce battery pack life NOTE The battery switch may be le...

Страница 27: ...he threaded blower inlets as shown in Figure 19 Figure 19 Blower Inlet Gaskets 2 If installing chemical cartridges remove the screw cap and plug from each cartridge Retain for reuse 3 Install the thre...

Страница 28: ...DO NOT USE the PAPR Have the PAPR repaired by the SPERIAN factory repair center Using a PAPR that is operating improp erly may result in illness or death b Belt mounted PAPR Configuration Pre opera t...

Страница 29: ...p erating improperly may result in illness or death 4 Donning Instructions for PAPR Configurations WARNING Always don remove and fit check the respirator in a safe uncontami nated area Prior to donnin...

Страница 30: ...e neck strap if installed over your head 8 Place your chin against the chin cup and center the facepiece on your face See Figure 25 Figure 25 Place Chin in Chin Cup Hold the facepiece against your fac...

Страница 31: ...airflow from the blower for both the mask mounted and belt mounted PAPR configurations the wearer can safely breathe through the blow er filter assembly until reaching an uncon taminated area WARNING...

Страница 32: ...hange out schedule OSHA provides a rule of thumb method for determining the cartridge service life for mix tures The method addresses two situations The first is where the in dividual compounds of the...

Страница 33: ...E filter as follows 1 Return to fresh air 2 Remove the combination cartridges or HE filter from the blower by turning counter clockwise Dispose of used cartridges in accordance with Federal state and...

Страница 34: ...he hook latch and pulling the blower free of the facepiece Take care not to lose the o ring inside the blower connector c Immerse the facepiece top first in the solution until the exhalation valve is...

Страница 35: ...Repair by the user is limited to replacement of com ponents listed in the Repair Tables of Section XV and as listed on the NIOSH approval lavel Disassembly should be performed only to the extent neces...

Страница 36: ...MPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE CONDITIONS To maintain this warranty this product must be used maintained and inspected as prescribed in the owner s instruction...

Страница 37: ...5 Cuts nicks abrasions or excess stretching to the Nozzle Adapter O rings O RINGS TWIN SEALS Cuts nicks abrasions or excess stretching CARTRIDGE CONNECTORS 1 Cracks heat or impact damage 2 Cuts nicks...

Страница 38: ...and facepiece turning on the blower and passing a fit test ampule P N 140098 near the facepiece breathing tube and blower If the wearer detects the banana oil odor a leak is detected Battery and Cord...

Страница 39: ...er upward 3 To install engage the cover on the nozzle upper hook 4 Rotate cover downward until both lower latches engage the cover An au dible click should be heard Nozzle 1 Remove the nozzle cover as...

Страница 40: ...www sperianprotection com...

Отзывы: