WARNING

TORNADO powered respirators are designed for use by personnel who are
familiar with workplace hazards.

This leaflet must be read together with the user leaflet for T/POWER and
T/FILTER.

DO NOT use in confined spaces, oxygen deficient atmospheres (<19.5%),
oxygen enriched atmospheres (>23%) or areas where there is an immediate
DANGER to life or health

DO NOT use if the mask or air hose is damaged, the filter is clogged or the
filter is time expired (see filter label).

DO NOT use with a low airflow output.

T7/VISION 2 is not approved for use with T/A/LINE.

DO NOT modify facemasks as this will invalidate all approvals and may
result in death or injury to the wearer.

Protection will only be obtained if the unit is fitted correctly.

In the unlikely event of T/Power failing while in a hazardous atmosphere,
there may be a reduction in airflow within the facepiece.  DO NOT remove
the facepiece.  GO IMMEDIATELY to a safe area then remove the facepiece.

It is unlikely that the requirements for leakage will be achieved if hair,
spectacle side arms or clothing intrude into the faceseal.

T7/VISION 2  SPECIFICATION

Facepiece

T7/VISION-S/M/ML

   Description

Full Facemask

   Classification:         

T7/VISION 2

                                     

Visor

EN 12942 TM3
Meets impact requirements of EN 166 Grade B

   Minimum design flow rate

110 L/min

   Assigned* protection factor

   Nominal protection factor

40

2,000

   Operating temperature range

-10°C to 40°C

   Storage temperature range

10°C to 40°C

   Face seal material

Silicone elastomer

*According to BS4275 : 1997