SURVIVAIR Opti-Fit
™
Convertible Facepiece
8
Table 1. Air Purifying Respirator (APR) Filters and
Cartridges
Part No.
Protection/Description
Filters
1050
P100
1060
Filter Pad, N95
1070
Filter Pad, N99/R95
1190
P100 Slimline
1195
P100 Disk
Cartridges
100100
Organic Vapors
100200
Acid Gases
100300
Organic Vapors and Acid Gases
100400
Ammonia and Methylamine
100600
Mercury Vapor and Chlorine
100800
Multi-contaminant
1051
Combination Organic Vapors and P100
1052
Combination Acid Gases and P100
1053
Combination Organic Vapors, Acid Gases, and P100
1054
Combination Ammonia, Methylamine, and P100
1056
Combination Multi-contaminant and P100
1058
Combination Multi-contaminant and P100
Table 2. Continuous Flow Supplied Air Respirator
(CF-SAR) Air Hose Components
Part No.
Item Description
930861
High performance hose—25 feet (requires quick coupler kit)
930862
High performance hose—50 feet (requires quick coupler kit)
930864
High performance hose—100 feet (requires quick coupler kit)
930801
Light weight hose—25 feet (requires quick coupler kit
930802
Light weight hose—50 feet (requires quick coupler kit
930804
Light weight hose—100 feet (requires quick coupler kit
985241
Light weight hose with OBAC couplings—25 feet
985242
Light weight hose with OBAC couplings—50 feet
985244
Light weight hose with OBAC couplings—100 feet
930810
Quick coupler kit—style: Foster
930820
Quick coupler kit—style: Schrader
930830
Quick coupler kit—style: Hansen
930840
Quick coupler kit—style: OBAC
Table 3. Powered Air Purifying Respirator (PAPR)
Belt-Mounted Cartridges
Part No.
Item Description
150100
OV Cartridge
150200
AG Cartridge
150300
OV/AG Cartridge
150400
AM/MA Cartridge
158100
OV/HEPA Cartridge
158200
AG/HEPA Cartridge
158300
OV/AG/HEPA Cartridge
158400
AM/MA/HEPA Cartridge
108000
HEPA Filter
APR Cartridge Considerations:
WARNING
The following is a partial list of materials
that have either poor warning proper-
ties, will develop high heats of reaction
with the sorbent in the canister, have
extremely short service times, or will
not be absorbed at all. Respirators can-
not be used to protect you against many
of these chemicals. Contact a certified
industrial hygienist or SPERIAN if you
have any of these materials present in
the work place. The use of a respirator
for these materials may lead to personal
injury, illness, or death.
Acroline
Carbonyls
Hydrogen
Selenide
Ozone
Aniline
Cyanogen
Isocyanates:
TDI, HDI, MDI
Phosgene
Arsine
Dimethylaniline
Methanol
Phosphine
Boron
Hydrides
Dimethyl Sulfate
Methyl
Bromide
Methyl
Chloride,
Methylene
Chloride
Phosphorous
Trichloride
Bromine
Ethyl Cyanide
Nitro
Compounds:
Nitrogen
Oxides
Nitroglycerin
Nitrobenzene
Nitromethane
Stibine
Carbon
Dioxide
Fluorine
Sulfur Chloride
Carbon
Monoxide
Hydrogen
Cyanide
Vinyl Chloride
VII. FACEPIECE PREPARATION USING INCLUDED
ITEMS
The SURVIVAIR Opti-Fit Convertible is shipped with
side connector port screw caps and a nozzle plug kit
that must be used to configure the facepiece for the
various operating configurations as detailed below.