4.LOW RESISTANCE (CONTINUITY)
MEASUREMENTS
a).
Set the range switch to 400
Ω
/BZ Position
b).
Connect the red test lead to the V
Ω
terminal and black to the
COM terminal.
c).
Connect the tips of the test leads to both ends of the circuit under
test. read resistance in
Ω
on the LCD.
The two
ranges(40.00/400.0
Ω
) can be switched automatically;
the
primary display of the resistance in
Ω
, flashes in synchronous
with the analog bar.
d).
When the impedance on circuit is below approximately
≤
35
Ω
.It
will indicate by a continuous beeper.
e)
The current is from 200 to 220mA while the tested resistance is
0
Ω
f)
T
he high voltage symbol “
“
flashes along with a primary
display of “>30V” and the buzzer warn
s frequently if the voltage
(AC/DC) is more than 30V.
5.AC/DC VOLTAGE MEASUREMENTS
a). Set the range switch to ACV or DCV position
b). Connect red test lead to “V
Ω
” terminal and black test lead to
terminal “COM”.
c). Connect test prods of test leads IN PARALLEL to the circuit being
measured.
d). Read the voltage value on LCD.
Содержание 420001