background image

2

2000 Series

Specifications

The Specifications section gives some general specifications for the 2000 Series Temperature Regulator. The 

nameplates give detailed information for a specific pilot as built in the factory.

On temperature increase, the vapor pressure of the 

liquid in the bulb increases, forcing liquid into the 

capillary and bellows and increases the pressure 

exerted on the bellows. On temperature decrease, 

the vapor pressure of the liquid in the bulb decreases 

withdrawing liquid from the bellows which reduces the 

pressure exerted on the bellows.
A balance is established between the force exerted 

by the bellows and the counteracting range spring 

force. On bellows pressure increase, the bellows 

volume expands, the compression of the range 

spring increases and the stem moves downward. 

On bellows pressure decrease, the bellows volume 

compresses, the range spring expands and the stem 

moves upward.
For a direct acting valve, an increase in bulb 

temperature closes the valve (heating). For a reverse 

acting valve, an increase in bulb temperature opens 

the valve (cooling).

1.  The pressure/temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.

SIZE,  

NPS / DN

ORIFICE

MAXIMUM UPSTREAM PRESSURE, PSIG / BAR

MAXIMUM DIFFERENCE 

BETWEEN INLET PRESSURE, 

PSIG / BAR

Single Seat, Types 2010 and 2020

Double Seat, Types 2030 and 2040

Three-way, Type 2050

1/2 / 15

C

250 / 17.2

N/A

N/A

1/2 / 15

D

1/2 / 15

E

1/2 / 15

A

1/2 / 15

B

200 / 13.8

1/2 / 15

T

140 / 9.7

250 / 17.2

140 / 9.7

3/4 / 20

T

90 / 6.2

90 / 6.2

1 / 254

T

65 / 4.5

65 / 4.5

1-1/4 / 32

T

40 / 2.8

40 / 2.8

1-1/2 / 40

T

30 / 2.1

30 / 2.1

2 / 50

T

20 / 1.4

20 / 1.4

Table 1

. 2000 Series Flow and Pressure Ratings

Available Configurations

Type 2010:

 Single seat, direct-acting

Type 2020:

 Single seat, reverse-acting

Type 2030:

 Double seat, direct-acting

Type 2040:

 Double seat, reverse-acting

Type 2050:

 Three-way mixing

Body Sizes

See Table 1

End Connection Style

NPT Union

Maximum Inlet Temperature

(1)

415°F / 213°C

Maximum Inlet Pressure

(1)

250 psig / 17.2 bar

Pressure Ratings

(1)

See Table 1

Bulb Ranges

(1)

See Table 5

Bulb Materials

Copper Bronze

Stainless steel

Fills

Iso-Butane

Ethylene-Glycol

N-Butane

Reclaimed R-123

N-Propyl-Alcohol

Toluene

Содержание 2000 Series

Страница 1: ...hall install or service the 2000 Series Temperature Regulator Introduction Scope of the Manual This instruction manual covers operation installation maintenance and troubleshooting for 2000 Series Temperature Regulator Product Description The 2000 Series is a self operated temperature regulator available with single or double seat in direct or reverse acting It is also available with two seat area...

Страница 2: ...For a reverse acting valve an increase in bulb temperature opens the valve cooling 1 The pressure temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded SIZE NPS DN ORIFICE MAXIMUM UPSTREAM PRESSURE PSIG BAR MAXIMUM DIFFERENCE BETWEEN INLET PRESSURE PSIG BAR Single Seat Types 2010 and 2020 Double Seat Types 2030 and 2040 Three way Type 2...

Страница 3: ...e the disk to close the bottom outlet of the valve and open the side outlet of the valve until temperature is balanced again For diverting service simply rotate the valve installation The diverter inlet is the outlet mixing Installation WARNING Failure of the thermal system or foreign material lodged between the valve s closure members can lead to an over temperature and or an over pressure condit...

Страница 4: ...vertical position with the thermal assembly on top Bulb The location of the bulb should be chosen carefully so that the temperature of the media around the bulb or well will be representative of the entire body of fluid being heated or cooled Note For all applications where the bulb is mounted in the horizontal position the red dot on the bulb must be facing upward When large volumes of oil are be...

Страница 5: ...re rise 5 Closes with increase in temperature rise INITIAL PRESSURE SPENCE SERIES 2000 TEMPERATURE REGULATOR SHUTOFF VALVE SPENCE STRAINER SHUTOFF VALVE SPENCE STRAINER SPENCE FTS STEAM TRAP CONDENSATE MAIN SPENCE STRAINER CHECK VALVE PRESSURE RELIEF VALVE CHECK VALVE HOT WATER SERVICE T P RELIEF VALVE SHUTOFF VALVE BULB STORAGE TANK TYPE 2050 INDICATING MIXING REGULATOR INLET 1 INLET 2 OUTLET 3 G...

Страница 6: ...r the bulb is inserted position it so that the red dot on the bulb is upward then tighten the jam nut to secure the bulb to the well Replacement Thermal Systems The vapor pressure in some systems is too high at ordinary ambient temperatures to permit removal of the shipping block without damage to the bellows To reduce the vapor pressure within safe limits the complete system bulb line and bellows...

Страница 7: ...138 167 310 337 9 122 152 145 177 317 347 10 129 158 157 183 322 353 REGULATOR SETTING RANGE C 7 2 to 46 7 2 to 63 18 to 60 18 to 77 116 to 154 116 to 171 0 1 7 10 18 21 113 116 2 14 21 27 33 121 131 3 22 31 33 42 129 138 4 27 39 39 52 135 147 5 33 46 46 58 141 153 6 38 51 51 64 146 159 7 42 57 55 70 151 165 8 46 62 59 75 154 169 9 50 67 63 81 158 175 10 54 70 69 84 161 178 Control points at these...

Страница 8: ...ed preset the regulator according to Table 3 The operating range of the regulator is indicated on the nameplate The setting scale is stamped on the side of the frame and is graduated 0 to 10 representing the limits of the operating range This is an arbitrary scale since it must necessarily vary for different temperature ranges Table 4 gives the approximate temperature equivalent for all scale sett...

Страница 9: ...Nut 14 Indicator Assembly 15 Adjusting Spring 16 Safety Spring Assembly 17 Guide 18 E Ring 19 Thermal System Assembly Maintenance The adjusting nut of each regulator is permanently lubricated before leaving the factory and the valve stem is equipped with a spring loaded Teflon packing gland assembly so that no maintenance should be required for the life of the regulator The valve stem is set and l...

Страница 10: ...T 1 1 4 T 1 1 2 T 2 T Union End Kit Single Seat Cast iron WAL2822 WAL2822 WAL2822 WAL2822 WAL2822 WAL2822 WAL2823 WAL2826 WAL2827 WAL2828 WAL2829 Union End Kit Double Seat Cast iron WAL2824 WAL2825 WAL2826 WAL2827 WAL2828 WAL2829 Union End Kit 3 Way Cast iron WAL2830 WAL2831 WAL2832 WAL2833 WAL2834 WAL2835 Body Assembly Kit 2010 Bronze 2010AC 2010BC 2010CC 2010DC 2010EC 2010TC 2010TD 2010TE 2010TF...

Страница 11: ... 11 12 13 14 15 16 17 18 19 11 2000 Series Figure 8 2000 Series Temperature Regulator Assembly THERMAL ASSEMBLY KIT SAFETY SPING KIT FRAME KIT INDICATOR KIT V PACKING KIT BONNET KIT STEM GUIDE KIT 2 SETS BODY ASSEMBLY KIT ...

Страница 12: ...s are property of their prospective owners The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability All sales are governed by our terms and conditions which a...

Отзывы: