5.
USER INTERFACE AND CONTROL
There are two ways the HVPS can be controlled. Using computer control with “GUI” Graphic
User Interface control Software via RS232, Ethernet or USB interface connected to the
HVPS. The second way is connecting the unit to J2 a manual analog controller. The Analog
controller must meet the interface requirement as indicated on page 18 (J2 I/O PINOUT) for
both analog and digital logic signals.
5.1.
Computer Interface
5.1.1.
RS-232 Digital Interface
– J3, 9 pin D, female connector
Pin
Signal
Parameters
1
NC
2
TX out
Receive data (user)
3
RX in
Transmit data (user)
4
NC
5
SGND Ground
6
NC
7
NC
8
NC
9
NC
Communication Parameters:
XRV SERIES
Page 16
118116-001 REV C