V6 Series MANUAL
7
118130-001 REV C
Figure 2
Grounding DC Unit
V6D Unit
High Voltage Connection
Load Return Connection
System Ground
Customer
Load
HV
Out
GND
Stud
J1-13
Power Ground Return
Power Input
J1-15
J1-6
Signal Ground
Figure 3
Grounding AC Unit
V6A Unit
High Voltage Connection
Load Return Connection
System Ground
Customer
Load
HV
Out
GND
Stud
J2-L
J2-G
J2-N
Line
Ground
J1-6
Signal Ground
Neutral
AC Input
Power
Figure 4
Remote Programming with a Remote Voltage Source
Vprg / Iprg: 0 to 5Vdc = 0 to 100% Rated Output
V6 Unit
High Voltage Connection
Load Return Connection
System Ground
Customer
Load
HV
Out
GND
Stud
J1-9
I Program
V Program
J1-6
Signal Ground
DC
+
-
DC
+
-
J1-4
Figure 5
Programming using the +5V Reference
If one pot is not used connect the other programing input directly to +5V Reference J1-7
V6 Unit
High Voltage Connection
Load Return Connection
System Ground
Customer
Load
HV
Out
GND
Stud
J1-7
+5V REF
I Pgm
J1-9
J1-6
Signal Ground
J1-4
V Pgm
I Pgm
10K
Ω
10K
Ω