V6 Series MANUAL
9
118130-001 REV C
Chapter 4
Principles of Operation
Warning!
The energy levels used and generated by the
power supply can be lethal! Do not attempt to
operate the power supply unless the user has
sufficient knowledge of the dangers and hazards
of working with high voltage. Do not attempt to
approach or touch any circuits that are
connected to or have been connected to the
power supply. Be certain to discharge any stored
energy that may be present before and after the
power supply is used. Consult IEEE
recommended practices for safety in high
voltage testing document number 510-1983.
4.1 DC/AC Input
The V6 Series is a DC to DC converter. Within the power
supply conversions from low voltage DC, to low voltage
AC, to high voltage AC and finally to high voltage DC
takes place. The DC input +24Vdc powers the power
conversion circuitry that creates the high voltage output
along with the low voltage DC housekeeping voltages that
provide power to the affiliated support control circuitry.
The AC units use an off the shelf universal input 24V
switching power supply.
4.2 Inverter
The DC input voltage is fed to the Inverter circuitry. Here
the low voltage DC is converted to a low voltage, high
frequency AC signal. This power conversion step allows
for all subsequent power processing to take advantage of
component miniaturization due to the high operational
frequency. The Inverter functionality is controlled via the
power supply’s regulating loops which allows for
complete command of the desired output voltage and
current.
4.3 High Voltage Transformer
The high voltage transformer is a ferrite core step up type
in which the primary is driven from the output of the
Inverter circuit. The secondary of the high voltage
transformer feeds the High Voltage Output Section.
4.4 High Voltage Output Section
The High Voltage Output Section utilizes an arrangement
of half wave Cockcroft-Walton voltage multiplier stages
to obtain the necessary output voltage.
The actual output voltage is sampled via a high
impedance divider to create a voltage feedback signal. A
current feedback signal is created via a current sense
resistor in the low end return of the High Voltage Output
Circuitry. These two accurate ground referenced feedback
signals are used to precisely regulate and control the unit,
in addition to providing external monitoring.
4.5 Control Circuitry
Various SMT based control circuitry is used for all
interfacing, monitoring and regulation functionality of the
V6 modular power supply.
The voltage and current feedback signals generated in the
High Voltage Output Section are compared to the
requested voltage and current commands from the remote
interface. The voltage or current loop error amplifier
creates the appropriate error signal which is then provided
to the Pulse Width Modulation (PWM) circuitry.
The output of the PWM circuitry drives the Inverter
circuit to provide the required output in a continuous
closed loop control process, regulating in either voltage
mode or current mode as required.