![Spellman V6 Series Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/spellman/v6-series/v6-series_instruction-manual_1346481029.webp)
Standard V6 Series Communication Protocol
8
118109-001 REV B
5.3 COMMAND OVERVIEW
Command Name
<CMD>
<ARG>
RANGE
Program KV (DAC
A)
10
1-4 ASCII
0-4095
Program Output
Current (DAC B)
11
1-4 ASCII
0-4095
Request ADC Data
20
None
-
Request Status
22
None
-
Request Software
Version
23
None
-
Request Hardware
Version
24
None
-
Request Model
Number
26
None
-
Set H.V. OnOff
99
1 or 0
-
5.4 RESPONSE
OVERVIEW
The command responses will follow the same format as outlined above in
section 5.3. This list is comprised of Commands with complex responses
only. Commands using a simple response will use the <$> character
(ASCII 0x24) as a “Success” response or a single character error code.
These responses will be eight ASCII characters in length.
Response Name
<CMD>
Response
Request Analog
Readbacks – KV &
MA
20
20-41
ASCII
Request Status
22
12 ASCII
Request DSP
Software Version
23
18 ASCII
Request Hardware
Version
24
10 ASCII
Request Model
number
26
12 ASCII