Step 4: Connect Drain Hose to Drain 
Receptacle

Remove the drain hose from its shipping position on 

the rear of the washer by unhooking the hose from the 

retainer clamp and by removing the shipping tape.
Install the drain hose into the drain receptacle 

(standpipe, wall or laundry tub) following the 

instructions below.

IMPORTANT: Drain receptacle must be capable of 

handling a minimum of 1-1/4 inch (3.2 cm) outside 

diameter drain hose.

Standpipe Installation:

Place the drain hose into the standpipe.
Remove the beaded strap from accessories bag and 

place around standpipe and drain hose and tighten 

strap to hold hose to standpipe. Refer to 

Figure 6

. This 

will prevent the drain hose from dislodging from drain 

receptacle during use.

Wall Installation:

For installations of this type, the drain hose MUST be 

secured to one of the fill hoses using the beaded strap 

from accessories bag. Refer to 

Figure 7

.

NOTE: End of drain hose must not be below 24 in.

(61 cm).

FLW1990N

Water Faucets

2

Cold Water Connection

3

Hot Water Connection

4

Fill Hoses

Figure 5 

Drain Flow Rate

Drain Height

Flow Rate

gallons per minute

(liters per minute)

3 ft. (0.9 m)

8.19 (31)

5 ft. (1.5 m)

7.27 (27.5)

6 ft. (1.8 m)

6.31 (23.9)

7 ft. (2.1 m)

4.89 (18.5)

8 ft. (2.4 m)

2.79 (10.6)

FLW1990N

1

2

3

4

FLW1992N

24 in. to 36 in. (91.44 cm recommended 
height)

2

Standpipe - 2 in. (5.08 cm) or 1-1/2 in. (4 cm) 

3

Beaded Strap

Figure 6 

H023I

Drain Hose

2

Beaded Strap (tape if necessary)

3

Fill Hoses

Figure 7 

FLW1992N

1

2

3

3

1

2

Содержание 802758R4

Страница 1: ...chine changes ownership this manual must accompany machine www speedqueen com Installation Instructions for Frontload Washers Washer Dimensions 2 Before You Start 2 Installation 3 Installer Checklist Back Cover Date Purchased ________________ Model Number ________________ Serial Number ________________ Part No 802758R4 April 2012 Inside ...

Страница 2: ...er is delivered on a cold day below freezing or is stored in an unheated room or area during the cold months do not attempt to operate it until the washer has had a chance to warm up NOTE Some moisture in the wash drum is normal Water is used during testing at the manufacturer NOTE Install dryer before washer This allows room for attaching exhaust duct FLW2224N Figure 1 FLW2224N 2 in 5 1 cm 26 875...

Страница 3: ...her is not level tilt washer to access the front and rear leveling legs Loosen the locknuts and adjust legs by screwing into or out of washer base Make sure that the washer does not rock When washer is level and does not rock tighten locknuts securely against bottom of washer base If these locknuts are not tight washer will move out of position during operation Do not slide washer across floor onc...

Страница 4: ...must be facing outward Screw hose couplings with the filter screens onto the water faucets until they are finger tight Then using a pliers screw approximately 1 4 turn Use the red color coded hose for the hot water connection and the blue color coded hose for the cold water connection Screw hose couplings from other end of hoses onto the water mixing valve until they are finger tight Then using a ...

Страница 5: ...ten strap to hold hose to standpipe Refer to Figure 6 This will prevent the drain hose from dislodging from drain receptacle during use Wall Installation For installations of this type the drain hose MUST be secured to one of the fill hoses using the beaded strap from accessories bag Refer to Figure 7 NOTE End of drain hose must not be below 24 in 61 cm FLW1990N 1 Water Faucets 2 Cold Water Connec...

Страница 6: ...8 Use the beaded strap supplied in accessories bag to secure hose Step 5 Remove the Shock Sleeves and Shipping Brace 1 Remove panel Figure 9 2 Remove brace Five bolts secure brace to machine For easier removal remove in order shown Figure 10 3 Remove shock sleeves Figure 11 4 Replace panel Figure 12 FLW1994N 1 Drain Hose 2 Beaded Strap tape if necessary Figure 8 FLW2269N 1 2 FLW2269N FLW2270N FLW2...

Страница 7: ...t from inside the drum Step 7 Plug in the Washer Washer requires 120 Volt 60 Hertz electrical supply and comes equipped with a 3 prong grounding plug Refer to serial plate for specific electrical requirements When plugging in the washer DO NOT overload circuits DO NOT use an extension cord DO NOT use an adapter DO NOT operate both a washer and gas dryer on the same circuit Use separately fused 15 ...

Страница 8: ...ectrician check the polarity of the wall receptacle If a voltage reading is measured other than that in Figure 15 the qualified electrician should correct the problem NOTE The wiring diagram is located in the control hood Step 8 Check Installation Refer to Installer Checklist on the back cover of this manual and make sure that washer is installed correctly Run the washer with a test load to make s...

Страница 9: ......

Страница 10: ...LW2165N Position and Level the Washer 2 CHECK FLW2165N Connect Fill Hoses FLW2054N COLD HOT 3 CHECK Filter Screens Cold Valve Connection Plain Washers Red Blue Hot Valve Connection FLW2054N Connect Drain Hose to Drain Receptacle 4 CHECK FLW1992N FLW1992N Remove the Shock Sleeves and Shipping Brace 5 CHECK FLW2124N FLW2124N FLW2166N Wipe Out Inside of Washer Drum 6 CHECK FLW2166N D254I Plug in the ...

Отзывы: