Speed Queen 802758R4 Скачать руководство пользователя страница 3

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

3

802758

Installation

Step 1: Position Washer Near Installation 
Area

Move washer as close to the desired area of 

installation as possible.

NOTE: For best performance and to minimize 

vibration or movement, install washer on a solid, 

sturdy and level floor. Some floors may need to be 

reinforced, especially on a second floor or over a 

basement. Do not install the washer on carpeting, 

soft tile, a platform or other weakly supported 

structures.

Step 2: Position and Level the Washer

Position washer so it has sufficient clearance for 

installation and servicing.

NOTE: Use of the dispenser drawer or washer door 

as a handle in the transportation of the washer may 

cause damage to the dispenser or door.

Place washer in position on a solid, sturdy and level 

floor. Installing the washer on any type of carpeting, 

soft tile, a platform or other weakly supported 

structures is not recommended.
For easier access to leveling legs, prop up washer with 

a wooden block. Refer to 

Figure 3

.

 

Place a level on the cabinet top and check if the 

washer is level from side to side and front to back.

NOTE: Level must rest on raised portion of top 

panel. Refer to 

Figure 3

.

If washer is not level, tilt washer to access the front 

and rear leveling legs. Loosen the locknuts and adjust 

legs by screwing into or out of washer base.
Make sure that the washer does not rock. When 

washer is level and does not rock, tighten locknuts 

securely against bottom of washer base. If these 

locknuts are not tight, washer will move out of 

position during operation.
Do not slide washer across floor once the leveling legs 

have been extended. Legs and base could become 

damaged.
Place rubber feet (supplied in accessories bag) on all 

four leveling legs. Refer to 

Figure 3

Verify that washer does not rock.

Step 3: Connect Fill Hoses

FLW2291N

Level

2

Wood Block

3

Rubber Foot

4

Leveling Leg

5

Locknut

6

Washer Base

Figure 3 

Mixing Valve Flow Rates

Pressure

(psi)

HOT 

gallons per minute

(liters per minute)

COLD 

gallons per minute

(liters per minute)

20

1.6 (6)

2.5 (9.4)

40

2.2 (8.2)

3.4 (13)

60

2.6 (9.9)

3.8 (14.5)

100

2.5 (9.6)

4.2 (15.9)

120

2.6 (9.8)

4.2 (15.9)

FLW229

1

5

3

4

6

2

Under certain conditions, hydrogen gas 

may be produced in a hot water system 

that has not been used for two weeks or 

more. HYDROGEN GAS IS EXPLOSIVE. If 

the hot water system has not been used 

for such a period and before using the 

washer, turn on all hot water faucets and 

let the water flow from each for several 

minutes. This will release any 

accumulated hydrogen gas. The gas is 

flammable. Do not smoke or use an open 

flame during this time.

W029

WARNING

Содержание 802758R4

Страница 1: ...chine changes ownership this manual must accompany machine www speedqueen com Installation Instructions for Frontload Washers Washer Dimensions 2 Before You Start 2 Installation 3 Installer Checklist Back Cover Date Purchased ________________ Model Number ________________ Serial Number ________________ Part No 802758R4 April 2012 Inside ...

Страница 2: ...er is delivered on a cold day below freezing or is stored in an unheated room or area during the cold months do not attempt to operate it until the washer has had a chance to warm up NOTE Some moisture in the wash drum is normal Water is used during testing at the manufacturer NOTE Install dryer before washer This allows room for attaching exhaust duct FLW2224N Figure 1 FLW2224N 2 in 5 1 cm 26 875...

Страница 3: ...her is not level tilt washer to access the front and rear leveling legs Loosen the locknuts and adjust legs by screwing into or out of washer base Make sure that the washer does not rock When washer is level and does not rock tighten locknuts securely against bottom of washer base If these locknuts are not tight washer will move out of position during operation Do not slide washer across floor onc...

Страница 4: ...must be facing outward Screw hose couplings with the filter screens onto the water faucets until they are finger tight Then using a pliers screw approximately 1 4 turn Use the red color coded hose for the hot water connection and the blue color coded hose for the cold water connection Screw hose couplings from other end of hoses onto the water mixing valve until they are finger tight Then using a ...

Страница 5: ...ten strap to hold hose to standpipe Refer to Figure 6 This will prevent the drain hose from dislodging from drain receptacle during use Wall Installation For installations of this type the drain hose MUST be secured to one of the fill hoses using the beaded strap from accessories bag Refer to Figure 7 NOTE End of drain hose must not be below 24 in 61 cm FLW1990N 1 Water Faucets 2 Cold Water Connec...

Страница 6: ...8 Use the beaded strap supplied in accessories bag to secure hose Step 5 Remove the Shock Sleeves and Shipping Brace 1 Remove panel Figure 9 2 Remove brace Five bolts secure brace to machine For easier removal remove in order shown Figure 10 3 Remove shock sleeves Figure 11 4 Replace panel Figure 12 FLW1994N 1 Drain Hose 2 Beaded Strap tape if necessary Figure 8 FLW2269N 1 2 FLW2269N FLW2270N FLW2...

Страница 7: ...t from inside the drum Step 7 Plug in the Washer Washer requires 120 Volt 60 Hertz electrical supply and comes equipped with a 3 prong grounding plug Refer to serial plate for specific electrical requirements When plugging in the washer DO NOT overload circuits DO NOT use an extension cord DO NOT use an adapter DO NOT operate both a washer and gas dryer on the same circuit Use separately fused 15 ...

Страница 8: ...ectrician check the polarity of the wall receptacle If a voltage reading is measured other than that in Figure 15 the qualified electrician should correct the problem NOTE The wiring diagram is located in the control hood Step 8 Check Installation Refer to Installer Checklist on the back cover of this manual and make sure that washer is installed correctly Run the washer with a test load to make s...

Страница 9: ......

Страница 10: ...LW2165N Position and Level the Washer 2 CHECK FLW2165N Connect Fill Hoses FLW2054N COLD HOT 3 CHECK Filter Screens Cold Valve Connection Plain Washers Red Blue Hot Valve Connection FLW2054N Connect Drain Hose to Drain Receptacle 4 CHECK FLW1992N FLW1992N Remove the Shock Sleeves and Shipping Brace 5 CHECK FLW2124N FLW2124N FLW2166N Wipe Out Inside of Washer Drum 6 CHECK FLW2166N D254I Plug in the ...

Отзывы: