background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

802758

4

Water Supply

Water supply faucets must fit standard 3/4 inch

(19.1 mm) female garden hose couplings. DO NOT 

USE SLIP-ON OR CLAMP-ON CONNECTIONS.
Water supply faucets should be readily accessible to 

permit turning them off when washer is not being 

used.
Recommended cold water temperature is 60

to 80

Fahrenheit (16

o

 to 27

o

 Celsius). Recommended 

maximum hot water temperature is 125° Fahrenheit 

(51° Celsius). Warm water is a mixture of hot and cold 

water. Warm water temperature is dependent upon 

water temperature and pressure of both the hot and 

cold water supply lines.

Water pressure must be a minimum of 20 to a 

maximum of 120 pounds per square inch (138 to 827 

kPa) static pressure measured at the faucet.

NOTE: Water pressure under 20 pounds per 

square inch (138 kPa) will cause an extended fill 

time in the washer and may not properly flush out 

the detergent dispenser.

Turn on the water faucets and flush the lines for 

approximately two minutes to remove any foreign 

material that could clog the screens in the water 

mixing valve.

NOTE: When installing in newly constructed or 

renovated buildings, it is very important to flush 

the lines since build-up may have occurred during 

construction.

Connecting Hoses

Remove the two plain rubber washers and two filter 

screens from the accessories bag. Install them into 

each end of the fill hoses as shown in 

Figure 4

. The 

screen must be facing outward.
Screw hose couplings with the filter screens onto the 

water faucets until they are finger-tight. Then, using a 

pliers, screw approximately 1/4 turn. Use the red 

color-coded hose for the hot water connection and the 

blue color-coded hose for the cold water connection.

Screw hose couplings from other end of hoses onto the 

water mixing valve until they are finger-tight. Then, 

using a pliers, screw approximately 1/4 turn. Refer to 

Figure 5

. Make sure the red color-coded hose from the 

hot water faucet goes to the water mixing valve 

marked “H” and the blue color-coded hose from the 

cold faucet goes to the valve marked “C”.

 

IMPORTANT: Do not cross thread or overtighten 

couplings. This will cause them to leak.

Turn water on and check for leaks. If leaks are found, 

turn off the water, unscrew hoses and reinstall them 

until there are no leaks. 

IMPORTANT: Turn off water supply whenever 

there will be an extended period of non-use.

 

IMPORTANT: Hoses and other natural rubber 

parts deteriorate after extended use. Hoses may 

develop cracks, blisters or material wear from the 

temperature and constant high pressure they are 

subject to.

All hoses should be checked on a monthly basis for 

any visible signs of deterioration. Any hose showing 

the signs of deterioration listed above should be 

replaced immediately. All hoses should be replaced 

every five years.

To prevent personal injury, avoid contact 

with inlet water temperatures higher than 

125

°

 Fahrenheit (51

°

 Celsius) and hot 

surfaces.

W748

WARNING

TLW1976N

Water Faucet

2

Blue Fill Hose

3

Plain Rubber Washer

4

Hose Coupling

5

Red Fill Hose

6

Filter Screens

Figure 4 

HOT

COLD

3

1

6

2

4

5

Содержание 802758R4

Страница 1: ...chine changes ownership this manual must accompany machine www speedqueen com Installation Instructions for Frontload Washers Washer Dimensions 2 Before You Start 2 Installation 3 Installer Checklist Back Cover Date Purchased ________________ Model Number ________________ Serial Number ________________ Part No 802758R4 April 2012 Inside ...

Страница 2: ...er is delivered on a cold day below freezing or is stored in an unheated room or area during the cold months do not attempt to operate it until the washer has had a chance to warm up NOTE Some moisture in the wash drum is normal Water is used during testing at the manufacturer NOTE Install dryer before washer This allows room for attaching exhaust duct FLW2224N Figure 1 FLW2224N 2 in 5 1 cm 26 875...

Страница 3: ...her is not level tilt washer to access the front and rear leveling legs Loosen the locknuts and adjust legs by screwing into or out of washer base Make sure that the washer does not rock When washer is level and does not rock tighten locknuts securely against bottom of washer base If these locknuts are not tight washer will move out of position during operation Do not slide washer across floor onc...

Страница 4: ...must be facing outward Screw hose couplings with the filter screens onto the water faucets until they are finger tight Then using a pliers screw approximately 1 4 turn Use the red color coded hose for the hot water connection and the blue color coded hose for the cold water connection Screw hose couplings from other end of hoses onto the water mixing valve until they are finger tight Then using a ...

Страница 5: ...ten strap to hold hose to standpipe Refer to Figure 6 This will prevent the drain hose from dislodging from drain receptacle during use Wall Installation For installations of this type the drain hose MUST be secured to one of the fill hoses using the beaded strap from accessories bag Refer to Figure 7 NOTE End of drain hose must not be below 24 in 61 cm FLW1990N 1 Water Faucets 2 Cold Water Connec...

Страница 6: ...8 Use the beaded strap supplied in accessories bag to secure hose Step 5 Remove the Shock Sleeves and Shipping Brace 1 Remove panel Figure 9 2 Remove brace Five bolts secure brace to machine For easier removal remove in order shown Figure 10 3 Remove shock sleeves Figure 11 4 Replace panel Figure 12 FLW1994N 1 Drain Hose 2 Beaded Strap tape if necessary Figure 8 FLW2269N 1 2 FLW2269N FLW2270N FLW2...

Страница 7: ...t from inside the drum Step 7 Plug in the Washer Washer requires 120 Volt 60 Hertz electrical supply and comes equipped with a 3 prong grounding plug Refer to serial plate for specific electrical requirements When plugging in the washer DO NOT overload circuits DO NOT use an extension cord DO NOT use an adapter DO NOT operate both a washer and gas dryer on the same circuit Use separately fused 15 ...

Страница 8: ...ectrician check the polarity of the wall receptacle If a voltage reading is measured other than that in Figure 15 the qualified electrician should correct the problem NOTE The wiring diagram is located in the control hood Step 8 Check Installation Refer to Installer Checklist on the back cover of this manual and make sure that washer is installed correctly Run the washer with a test load to make s...

Страница 9: ......

Страница 10: ...LW2165N Position and Level the Washer 2 CHECK FLW2165N Connect Fill Hoses FLW2054N COLD HOT 3 CHECK Filter Screens Cold Valve Connection Plain Washers Red Blue Hot Valve Connection FLW2054N Connect Drain Hose to Drain Receptacle 4 CHECK FLW1992N FLW1992N Remove the Shock Sleeves and Shipping Brace 5 CHECK FLW2124N FLW2124N FLW2166N Wipe Out Inside of Washer Drum 6 CHECK FLW2166N D254I Plug in the ...

Отзывы: