STEP
7
Install RO System and Drain In Remote Location
IINSTALL A REMOTE DRAIN POINT AND AIR GAP (Remote Location)
You can also run the drain tubing to an existing drain in the house. A floor drain, laundry tub, standpipe,
sump, etc. are suitable drain points.
Always be sure to provide an air gap between the end of the hose and the drain point. This will prevent
water from backing up into the system.
TO INSTALL A REMOTE DRAIN POINT, COMPLETE THE FOLLOWING STEPS:
1
Remove the 1/4" Red Plastic Tubing
R
from the RO Tap Body
P
by pulling gently.
2
Determine if this length is long enough to reach the drain point. If it is, then insert Restrictor
I
in end of
tubing and then insert this end of tubing into drain port on RO Membrane Filter
B2
.
3
If not, replace the 1/4" Red Plastic Tubing
R
with an adequate length of tubing to reach the drain point.
Then insert Restrictor
I
in end of tubing and then insert this end of tubing into drain port on RO
Membrane Filter
B2
. Refer to Step 6 in manual on how to disconnect and connect tubing.
4
Run the tubing to the drain point and secure at the end with a bracket (purchased locally).
Provide a 1-1/2” air gap between the end of the tube and the drain.
5
Remove 3/8" White Plastic Tubing
T
from RO Tap Body
P
and discard.
6
Tap will not have 1/4” or 3/8” tubing attached to the airgap barbs in the RO Tap Body
P
for
remote installation.
10