Page 14
MAINTENANCE / SERVICE
Replacing The Battery Pack
A properly cared for lead acid battery pack should last for 800 charging cycles,
which is generally 4-5 years.
IMPORTANT:
It is critical that the batteries be replaced with sealed gel cell
or AGM type lead acid type batteries. Standard wet lead acid batteries will leak,
and may be explosive. If you have questions about replacement batteries call
Spectrum at1-800 290 2833.
To change out the battery pack, you will need a Phillips screw driver and two
7/16” wrenches.
1. Drain the fresh water, and recovery tanks
2. Turn off the manual water valve
3. Open the battery cover door and pull
off the tubing that connects to the fresh
water filter to the solenoid
4. Close the battery cover
5. Remove these 4 screws. There are two
screws on each side
FOR PARTS AND SERVICE 1-800-290-2833